Basic waterproof area
the basic waterproof area in general, what are some components?
Raft plate waterproof area
- bottom area - face area - sloped area - exterior raft plate plane area
base waterproof area
- Bottom area - Side area - Top area
single-base waterproof / anti-corrosion / pile mount waterproof area
- bottom surface Area , side area , top surface area
water pit waterproof area
the surface of the puddle in direct contact with the foundation usually needs to be waterproof, according to the different form of the puddle slope,
outside the pit waterproof surface is: bottom plane, bottom facade, bottom slope
. You can directly select the corresponding code on each side of the puddle. The inner wall of the puddle and the bottom plate of the pit also need to be waterproofed, and the amount of work that can be extracted from the waterproof area using the template area code in the pit
China
.
the basic waterproof engineering quantity
understand the calculation method of the basic waterproof components, then the basic waterproofing how to produce? Take the raft board foundation as an example
in the software is a set of practices, select the form of engineering volume code, the code needs to select the slope area code in the engineering volume expression, the bottom area code, the outer raft board plane area code outside the outer wall, the face area code.
the area of the raft plate waterproof can be seen in the view engineering calculation.
the water treatment at the intersection of the bottom surface of the raft plate and other components, the area of the protruding part after intersecting the other components in the calculation rules is combined into the bottom area. The following figure:
common problem of basic waterproofing
1, raft plate waterproofing sleeve practice, why is there no external wall outside the raft plate flat area?
analysis of the cause of the first, inspection works, in the raft board foundation of the interior and exterior are drawn a circle of external walls, the outer circle of the wall properties and raft foundation is not connected, so there is no calculation.
Cause Analysis II, the properties of the outer ring wall must be the outer wall, and the outer wall must be enclosed into a closed area, (the base height of the outer wall must intersect with the raft board) so that the outside of the outer wall raft plate flat area.
"Calculating waterproofing" in the bar 2, bar base attribute?
"Whether to calculate waterproof" is the default calculation, so that the bar base can calculate the side area, bottom area and top surface area, convenient bar base waterproofing treatment, if set not calculated, will not be out of the side area, top area and bottom area of the amount.
3, how to set the column waterproof?
define the waterproof quota of the column sleeve, the engineering volume expression selects the bottom area plus the side area instead.
a waterproof protective layer between the 4th floor, the pad and the raft plate, how to deal with it?
use the mat layer to do, first do a layer of mat, intelligent arrangement, and then the height adjustment to the position of the mat layer, and then intelligently arrange a layer of mat, when waterproof protective layer can be.
5, how to arrange the waterproof area of the top of the base beam brick tire film?
can not be arranged, can only be in the table input reflects the amount of engineering, engineering volume expression inside there is no brick tire film top surface area of the code, so the software directly out of the amount.