echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Active Ingredient News > Drugs Articles > A list of the use of a fully enclosed intelligent bacteriological instrument.

    A list of the use of a fully enclosed intelligent bacteriological instrument.

    • Last Update: 2020-07-20
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com

    the bacteriological concentrator is through the principle of directional peristaltic pressure, so that the micro-porous membrane trapped in the test product snr0.22 m s 47mmor0.45 m x 47mm, by flushing the membrane to remove the antiseptic components, and then the required medium through the sample pipe directly into the full-enclosed filter culture culture, placed in the culture tank for sterile1
    , first take out our matching disposable incubator first check whether the packaging is intact, in the sterile room to open the packaging2, then plug the disposable culturer into the stainless steel drain tank one by one (several small holes on the instrument, each hole can be placed a petri dish)3, the one-time culturer's elastic hose loaded into the peristaltic pump head of the concentrator, the bacteriometer requires accurate positioning, the hose trend is smooth4, open the needle holes in the test bottle (bags) to be inspected and do ring disinfection, (if the test bottle sample, first the anchor part of the ring disinfection, and then open) the sample bottle (bag) positioning5, pull out the sample needle tube sheath, needle and test bottle mouth over alcohol lamp flame disinfection, insert the sample bottle, open the intelligent concentrator, the test bottle upside down, the implementation of the filter collection bacteria (should avoid the double-core needle tube intake membrane is soaked by the injection, affecting the intake;6 , after completing the collection, if the sample has a bacteriobacteria action or containpreservatives (according to the anti-bacterial sample sop , the next time to provide the bacterial sample of sop ) 7 , open the sterile of the medium bottle, the needle and the medium bottle mouth over the alcohol lamp flame disinfection, needle inserted into the medium bottle 8 , remove the plug of the top air filter opening of the disposable incubator, cover the bottom of the disposable incubator, open and close the hose in turn with a hose clip, open the bacteriometer, and inject the medium pump into the specified incubator (Take two clips to clamp the two tubes at the position of the elastic hose, first add the improved Martin medium, then take another clip to clip another tube, and clamp the hose attached to the disposable incubator with the clip, leaving the 5-6cm hose, cut the rest, and insert the opening end into the opening of the air filter.) 9 , respectively, in accordance with the pharmacopeia prescribed training time for training 10 , observe the culture, if sampling separation culture, can be disinfected hose, with sterile syringe inserted into the hose extraction required for further inspection .
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.