    Application of filter leak detection system

    • Last Update: 2016-03-18
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    HEPA generally refers to the filter with a collection efficiency of more than 99.97% for particles with a particle size greater than or equal to 0.3um It is usually used as the end filtration device in the clean workshop of pharmaceutical enterprises to provide clean air Whether the clean room can reach and maintain the designed cleanliness level is related to the performance and installation of the filter to a certain extent Therefore, it is one of the important means to test the filter in the clean workshop to ensure that it meets the requirements FDA also pointed out in the aseptic drug production guidelines that leakage test should be carried out after the filter is installed to check the tightness of filter gasket, frame, filter material, etc for the aseptic preparation production workshop, the filter leakage test should be carried out regularly 1 The filter efficiency of the filter itself for leakage detection is generally tested by the manufacturer, and the filter efficiency report and qualification certificate are attached when leaving the factory For pharmaceutical enterprises, filter leak detection refers to the on-site leak detection after the filter and its system are installed, mainly to check the small pinholes and other damages in the filter material, such as frame seal, gasket seal and the leak on the filter frame The purpose of leak detection is to check the tightness of the filter and its connection with the installation frame, find out the defects in the filter itself and installation in time, and take corresponding remedial measures to ensure the cleanliness of the area 2 Principle of DOP leak detection: the detection of the filter usually uses DOP generator to generate dust upstream of the filter, and uses photometer to detect the aerosol concentration upstream and downstream of the filter to determine whether the filter has leakage The purpose of dust generation is because the concentration of dust particles upstream of the filter is relatively low Only when particle counter is used to detect without dust generation, it is difficult to find any leakage Only when dust generation is supplemented can leakage be found obviously and easily The artificial aerosol DOP has a history of nearly 40 years For a period of time, because it is suspected to have carcinogenic effect on human beings, it is often replaced by the DOS (dioctylsebacate dioctyl sebacate) or dehs (DI (2-ethylxyl) sebacate) and Pao (polyaphaolefin polyolefin), but the experimental method is still called "DOP method" Because the concentration of atmospheric dust varies with place and time, sometimes it is larger, sometimes it is lower, so it is generally not used for leak detection FDA points out that the selected aerosol should meet certain physical and chemical requirements during leak detection, and should not use the aerosol that will cause microbial pollution and microbial breeding DOP generator can be divided into heat generation and cold generation Based on the principle of evaporation and condensation, the aerosol particles that are atomized are evaporated by heater, and condensed into tiny droplets under specific conditions After removing the oversized and undersized droplets, it leaves about 0.3um of fog DOP into the air duct, with particle size distribution of 0.1-0.3um The cold generator is a kind of multiphase DOP aerosol which uses compressed air to bubble in liquid and splashes through Laskin nozzle The particle size of Zui is about 0.65um Cold DOP is often used in filter leak detection There are two kinds of detection instruments, one is aerosol photometer, the other is particle counter The commonly used detection instrument in filter leak detection is aerosol photometer (hereinafter referred to as photometer), which is a kind of dispersive photometer It is composed of vacuum pump, light scattering chamber, photomultiplier tube, signal processing converter and micro place It is composed of manager, etc Its working principle is: when the air flow is pumped to the light scattering chamber by the vacuum pump, the particles in it scatter the light to the photomultiplier tube In photomultiplier tubes, light is converted into electrical signals, which are amplified and digitized and then analyzed by microprocessor to determine the intensity of scattered light Compared with the signal generated by the reference material, it can directly measure the mass concentration of particulate matter in the gas, so it is widely used However, the particle counter, whose test value reflects the concentration of the number of particles in the air flow and specifies the particle size range, has a high sensitivity and is applicable to all dust source aerosols There is a large choice, but it is seldom used in filter leakage detection, so it is difficult to quantitatively compare the test results of the two instruments 3 Detection method to determine whether there is obvious leakage in the filter itself and its installation, the following parts must be tested on site: filter material of the filter; the connection between filter material and its internal frame; between the gasket of filter frame and filter group support frame; between support frame and wall or ceiling 3.1 DOP leak detection materials and instruments include: dust source (PAO solvent), zr-1300 series aerosol generator, zr-6000 series aerosol photometer Aerosol generator (Pao, DOP generator) aerosol photometer (leak detector) the aerosol generator used by our company is a portable Laskin nozzle type aerosol generator, which directly uses air without compressed gas as power Under the working pressure of 20Pa, when the air velocity is 50-2025f3 / min, the multi dispersive submicron oil dust aerosol with the concentration of 10-100ug / ml can be produced The aerosol photometer used is ati2h type photometer, the dynamic measurement range is 0.00005 ~ 120ug / L, and the sampling flow is 1f3 / min (28.3l / min) 3.2 operation method 3.2.1 Introduce Pao aerosol on the upstream side of HEPA to be tested for HEPA in HVAC system, In order to make the concentration of aerosols uniform when they reach HEPA, they can be directly introduced from the negative pressure side of the system fan If they are to be introduced from the air duct, they should be introduced at least 10 times the diameter of the air duct from HEPA, and the bends should be minimized (iest) Generally, keep the upstream aerosol to reach the required concentration, and the concentration fluctuation in a certain range For HEPA on laminar flow hood and super clean platform, aerosol is directly introduced from the negative pressure side of the system fan 3.2.2 Initialize and set 100% and 0% reference standard values of aerosol photometer according to the operation requirements of aerosol photometer Connect the sampling tube with the upstream sampling port to measure the concentration of the upstream aerosol Adjust the aerosol concentration according to the operation requirements of the aerosol generator to make the upstream aerosol concentration reach (20-80) μ g / L 3.2.3 Scanning Leak Detection remove the diffuser of HEPA, and scan the sealing of the whole filter surface, between the filter and the frame, between the frame and the frame, and between the frame and the static pressure box When scanning, the distance between the sampling head and the filter surface is about 1 inch (about 2.54cm), and the scanning speed is not more than 5cm / s The scanning shall be conducted back and forth in a straight line, and the lines shall overlap During the detection, if there is an alarm sound (i.e the leakage rate exceeds 0.01%), it indicates that there is leakage The leakage shall be blocked with silica gel or tightened before scanning and inspection Check a filter for about 5-10 minutes During the test, always confirm the concentration of the upstream aerosol Pay attention to wearing protective mask and eye mask during the test 4 The result judgment and treatment filter leakage rate shall be less than or equal to 0.01% If the leakage rate of all points of HEPA is not more than 0.01% in the process of detection, then the HEPA is qualified; if one point is more than 0.01%, it is unqualified, and the point is marked out, which needs to be repaired or replaced Special glue is allowed to repair the leakage of filter material, but the area of single leakage shall not be greater than 1% of the total area, and the area of all leakage shall not be greater than 5% of the total area, otherwise it must be replaced 5 The leak detection cycle of filter FDA suggests that the leak detection should be conducted once every half a year in the sterile drug production guidelines, and once a year in the GMP Inspection Guidelines in China For the leakage detection of installed HEPA in iso14644-3:2005, the recommended Zui long time interval is 24 months DOP leakage detection shall be carried out after HEPA installation or replacement When the environmental monitoring shows that the air quality deteriorates, or the sterility test of the product fails, or the simulated filling test of the medium fails, the leakage can be detected as a part of the deviation investigation Filters to be leak tested also include HEPA for drying tunnels and ovens 6 Problem discussion 6.1 filter efficiency and leak detection filter efficiency refer to the efficiency of the filter itself, which varies with the standards and test methods implemented At present, the test methods for filter efficiency are: DOP method, which is not as sensitive as particle count method, and the relevant standards can be seen in the United States, iet-rp-cc001; particle count method, which uses particle counter as the detection instrument, uses single dispersion or multi dispersion aerosol, with high sensitivity, and is mostly used for super filter, and the relevant standards can be seen in iet-rp-cc007; The particle counter is used as the detection instrument for Zui MPPs, and the aerosol used is the same as before This method is stipulated in EN1822 standard of European Union The difference between the particle counter method and the particle counter method is that the particle size of Zui filter which is easy to penetrate is used as the particle size for testing; the sodium flame method uses the flame photometer to respond to the flame chroma of NaCl combustion For relevant standards, see "air passing through" in China The filter gb13554-92 "has low sensitivity, and NaCl is harmful to the quality of microelectronic products, which has not been used abroad For pharmaceutical enterprises, the filter leak detection is mainly on-site leak detection Through DOP method, the possible problems of filter itself, transportation and installation process are found Aerosol photometer and multi divergent aerosol are often used because they are more economical and convenient than monodisperse aerosol 6.2 aerosol photometer and particle count detector can use aerosol photometer or particle counter Particle counter detects the number distribution of particles, which is usually expressed in "particle / L" units, while photometer detects the mass concentration of particles, which is expressed in "mg / L" The particle size of Zui is not the same as that of Zui with large concentration, because the particle size and weight are in the third power, and the particle with large size takes a large proportion in the concentration distribution Therefore, when measuring the efficiency of the filter, the results obtained by using particle counter and photometer will be different Compared with the particle counter, the sensitivity and accuracy of the photometer are slightly poor, so it is not necessary to detect filters and ultrafilters above grade H13 For the field leak detection of filters in pharmaceutical enterprises, the photometer is widely used because of its convenience in use, easy to judge the detection results and sensitive to leak detection 6.3 in the determination of leak detection results, different standards are also different According to the American iest-rp-cc034, the field leakage transmissivity of class C and class D filters is 0.3um, and the photometer scanning method is 0.01 European Union EN1822 stipulates that the leakage test is qualified as long as the local transmittance of the filter under test does not exceed the specified local value The corresponding local transmittance of grade H13 filter is 0.25% However, it should be noted that the transmittance here is obtained by 0.3um single dispersion phase DOP test According to the "code for design of clean building GB50073-2001 and air filter gb13554-92", air dust or other aerosols are used for the leakage of the installed filter The leakage concentration is measured by particle counter For the filter, the penetration rate shall not be greater than 4 times of the qualified penetration rate of the filter For the leakage test of HEPA in pharmaceutical enterprises, if there is leakage in the actual test, the photometer value will increase significantly,
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.