echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Coatings News > Paints and Coatings Market > Coating standards: basic standards and general methods of Chinese coating products

    Coating standards: basic standards and general methods of Chinese coating products

    • Last Update: 2020-04-03
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    Core tip: the international standard and foreign advanced standard numbers and their degrees are replaced (abolished) by the standard numbers GB / t1720-1979 (1989) determination of film adhesion hg2-462-78 GB / t1721-1979 determination of appearance and transparency of varnish, clear oil and diluent hg2-498-77 GB / t1722-1992 determination of color of varnish, clear oil and diluent gb1722-79 GB/T17 Paint knowledge | precautions for wall paint color selection Recommended introduction: when painting the wall, the owner sometimes has difficulty in choosing what color of the wall paint to paint In fact, there is no ugly color in the wall paint, only the disharmonious color matching The use of wall color contains the knowledge of health Too strong color will stimulate people's perception, make people have a sense of fidgety, affect people's mental health Grasp the basic principles of wall color and paint a colorful space 1、 Wall paint color selection notice 1 Light color is generally used for the top surface Light colors make people feel light, dark colors make people feel heavy Usually, the treatment of rooms is from top to bottom, from shallow to deep For example, the ceiling and walls of rooms are white and Home of coatings: the name of Standard No is replaced (abolished) by international standard and advanced foreign Standard No GB / t1720-1979 (1989) paint film adhesion determination method hg2-462-78 GB / t1721-1979 varnish, clear oil and diluent appearance and transparency determination method hg2-498-77 GB / t1722-1992 varnish, clear oil and diluent color determination method gb1722-79 GB / t1723-1993 Coating viscosity determination method NEQ Г oct8420:1974 gb1723-79 GB / t1724-1979 (1989) coating fineness determination method hg2-501-77 GB / t1725-1979 (1989) coating solid content determination method hg2-502-77 GB / t1726-1979 (1989) coating covering power determination method hg2-503-77 GB / t1727-1992 general preparation method of coating gb1727-79 GB / t1728-1979 (1989) drying time determination of film and putty film Hg2-505-78 GB / t1730-1993 determination of film hardness Pendulum damping test neqiso1522:1973g1730-88 GB / t1731-1993 determination of film flexibility NEQ γ oct6806:1973g1731-88 GB / t1732-1993 determination of film impact resistance NEQ γ oct4765:1973g1732-88 GB / t1733-1993 determination of film water resistance NEQ γ oct9.043:1980gb1733-88 GB / t1734-1993 test method for vapor oil resistance of paint film NEQ Г oct9.043:1980gb1734-88 GB / t1735-1979 (1989) test method for heat resistance of paint film hg2-512-77 GB / t1736-1979 (1989) test method for preparation of insulating paint film hg2-50-78 GB / t1738-1979 (1989) test method for water absorption of insulating paint film hg2-55-78 GB / t1739-1979 (1989) test method for oil resistance of insulating paint film hg2-56-78 GB / t1740-1979 (1989) Test method for moisture and heat resistance of paint film hg2-739-78 GB / t1741-1979 (1989) test method for mould resistance of paint film hg2-740-78 GB / t1742-1979 (1989) test method for adhesive strength of glue solution hg2-783-78 GB / t1743-1979 (1989) test method for glossiness of paint film hg2-667-78 GB / t1746-1979 (1989) test method for moisture content of paint hg2-1027-77 GB / t1747-1979 (1989) test method for ash content of paint hg2-1028-77 GB / t1748-1979 (1989) test method for consistency of putty hg2-1029-77 GB / t1749-1979 (1989) test method for consistency of thick paint and putty hg2-1030-77 GB / t1750-1979 (1989) test method for leveling of paint hg2-1031-77 GB / t1751-1992 test method for whiteness of diluent and moisture-proof agent gb1751-79 GB / t1752-1979 (1989) test method for volatility of diluent and moisture-proof agent hg2-1033-77 GB / t1753-1979 (1989) determination of gel number of diluent and moisture-proof agent hg2-1034-77 GB / t1755-1979 (1989) determination of paint use hg2-1035-77 GB / t1758-1979 (1989) determination of paint use hg2-1038-77 GB / t1761-1979 (1989) determination of antifouling gas resistance of film hg2-1042-77 GB / t1762-1979 (1989) determination of film stickiness gb1762-79 GB / t1763-1979 (1989) Test method for chemical reagent resistance of paint film hg2-1144-78 GB / t1964-1979 (1989) test method for thickness of paint film hg2-1145-78 GB / t1965-1979 (1989) test method for preparation of paint film hg2-1146-78 GB / t1766-1995 rating method for aging of paints, varnishes and coatings neqso4682:1980 GB / t1766-79 (89) GB / t9277.1 ~ 9277.5-88 GB / t1768-1979 (1989) test method for abrasion resistance of paint film hg2-1174-78 GB / t1769-1979 (1989) test method for burnishing of paint film hg2-1183-78 GB / t1770-1979 (1989) test method for burnishing of primer and putty film hg2-1184-78 GB / t1771-1991 determination for neutral salt spray resistance of paints and varnishes neqiso7253: 1984gb1771-79 GB / t1865-1997 Paints and varnishes - artificial weathering and artificial radiation exposure (filtered xenon arc radiation) - neqso11341:1994 GB / t2705-1992 paint product classification, designation and type gb2705-81 GB / t3181-1995 paint film color standard GB / t3181-82 (89) gb3186-1982 (1989) paint product sampling - neqso1512:1974, etc GB / t5206.1-1985 Paints and varnishes vocabulary Part 1 general terms neqiso4618 / 1:1978 GB / t5206.2-1986 paints and varnishes vocabulary Part 2 resin terms neqiso / dis4618 / 3.2 GB / t5206.3-1986 paints and varnishes vocabulary Part 3 pigment terms GB / t5206.4-1989 paints and varnishes vocabulary Part 4 coating and coating film physical and chemical properties terminology neqiso4618 / 1:1984 GB / t5206.5-1991 Paints and varnishes -- Vocabulary -- Part 1: ill conditioned terms of paints and coatings -- neqso4618 / 2:1984 GB / t5207-1985 -- Determination of flash point of paints -- rapid equilibrium method for the determination of risk grade -- neqso3680:1983 GB / t5208-1985 -- rapid equilibrium method for the determination of flash point of paints and varnishes -- neqso3679:1983 GB / t5209-1985 -- Determination of water resistance of paints and varnishes -- immersion method -- neqso1521:1973 GB / t5210-1985 Determination of adhesion of coatings -- Faraday method neqso4624:1978 GB / t6739-1996 pencil method for film hardness -- eqvijsk5400:1990 GB / t6740-1986 determination of volatile and non-volatile substances in coatings -- eqviso3251:1974 GB / t6741-1986 uniform film preparation method (rotating applicator method) GB / t6742-1986 film bending test (cylindrical shaft) neqso1519:1972 GB / t6743-1986 Paints and varnishes - Determination of the acid value of paints - home of paints is devoted to news and information about paints, diatom mud, paints, coating processes, fire-resistant coatings, diatom mud, paints, coating processes, decoration knowledge and decoration renderings of fire-resistant coatings,
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.