    Common faults and solutions of salt spray box

    • Last Update: 2014-05-26
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    The application of salt spray box in actual production includes electronic and electrical engineering, scientific research institute, aerospace, automobile and motorcycle industry, coating Many industries such as parts for corrosion testing, can also be based on customer requirements Cass test box or cycle change of intelligent change salt spray box Salt spray box in the actual production has so many uses! So what are the common faults in the use process, and what are the solutions? 1 When the salt spray box suddenly fails during the test operation, the corresponding fault display prompt and audible alarm prompt appear on the control instrument The operator can quickly check the type of fault according to the chapter of troubleshooting in the operation and use of the equipment Generally, during the installation and debugging process, the operator will explain the simple maintenance If the fault is within the scope of the operator's ability, the operator can call the manufacturer for help at any time 2 If the temperature is too high, the PID setting parameters need to be set If the temperature rises directly and the over temperature is protected, the control instrument must be replaced if the controller fails 3 During the experiment of salt spray box, if the temperature change cannot reach the test temperature value, the electrical system can be checked and the faults can be eliminated one by one If the temperature rises very slowly, check the air circulation system to see if the regulating damper of the air circulation is opened normally Otherwise, check whether the motor of the air circulation is running normally 4 If the equipment fails to meet the test index, it is necessary to observe the temperature change, whether the temperature drops slowly, or the temperature tends to rise after reaching a certain value, and then make a solution according to the situation to see whether there are too many test samples in the studio, To make the working room unable to circulate, another common sense is to see how much the ambient temperature of the equipment is The temperature and humidity points of Zui are: 5 ℃ ~ + 30 ℃ ≤ 85% R.H
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.