    Correct operation steps of drum type ultrasonic bottle washing machine

    • Last Update: 2019-01-14
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    The drum type ultrasonic bottle washing machine can meet the cleaning needs of 2-500ml round bottle or special-shaped bottle, and is widely used in pharmaceutical, food and beverage fields Under the action of the thrust of the bottle supply turntable, the bottle is brought into the bottle washing machine by the dial First, the bottle enters the ultrasonic water tank for ultrasonic water bath rough washing, and then enters the fine washing track for alternate washing of two water, one steam or three water, one steam The bottle can be preliminarily dried and cleaned, which can meet the needs of mass production The high-frequency oscillation signal sent by the ultrasonic generator is converted into high-frequency mechanical oscillation by the transducer and transmitted to the medium cleaning solvent The ultrasonic radiation between the dense phases in the cleaning solution makes the liquid flow and generate tens of thousands of tiny bubbles These bubbles form and grow in the negative pressure area of ultrasonic longitudinal propagation, and close rapidly in the positive pressure area In the process of this so-called "cavitation" effect, bubble closure can form instantaneous high pressure of more than 1000 air pressure, which continuously generates instantaneous high pressure, just like a series of small "explosions" constantly impacting the surface of the object, so that the dirt in the surface and gap of the object can be peeled off quickly, so as to achieve the purpose of object surface purification Next, I'd like to share the operating procedures of this equipment: prepare (1) check whether the electrical switch, instrument indication and equipment transmission are normal (2) Check whether the clutch of the bottle puller is in the normal position If it is in the neutral position, please adjust it (3) Close the power switch of the machine, turn on the speed regulating switch, and the set frequency will be displayed on the fluorescent screen of the frequency converter operation panel At this time, press the run key, the frequency converter will work, and the motor speed will gradually reach the set value Stop pressing the stop key (4) Run the machine empty for 2 minutes first, check whether the equipment and mechanical transmission structure are normal, and whether the operation sound is normal, and then carry out production First, open the water inlet valve to make the reservoir full of water, open the valve without salt water, open the valve of water for injection, spray normally, open the water pump switch to make the ultrasonic cleaning tank full of water, adjust the water inlet to maintain a certain water level in the tank (it is strictly prohibited to open the ultrasonic wave below the water level), and open the air valve When the water level in the tank reaches the specified level, turn on the ultrasonic switch, and the ultrasonic cleaner enters the bottle washing state (1) The operator puts the Xilin bottle into the bottle feeding tray, turns on the speed regulating switch, makes the rotation speed be 10-26hz (100-400 PCS / min 7ml), and presses run key to start production (2) In case of bottle jamming, first press the stop key to stop, check the bottle jamming position, clean up the broken bottle in time, adjust the bottle puller, and then start the production (3) Put the vials into the bottle wheel and track on the bottle handling turntable Do not pour the vials into it Note (1) it is strictly forbidden to turn on the ultrasonic wave without reaching the water level (2) After the production, the ultrasonic must be turned off first, and then the water will be discharged (3) If the ultrasonic does not work, please ask professional maintenance personnel for maintenance (4) To adjust the production volume, please set the required working frequency according to the instructions of the frequency converter (5) Do not pour the bottle into the track The staff should strictly abide by the operating procedures of the ultrasonic bottle washing machine, so that the machine can reach a good operating state Through the introduction of the above editor, have you learned the correct operation steps of the drum type ultrasonic bottle washing machine? I also hope this article can help you.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.