    6 Inspection rules

    6.


    6.


    6.


    6.


    6.


    7 Marking, packaging, transportation and storage

    7.


    There should be a firm mark on the packaging container, which includes: the name of the manufacturer, site, product name, product grade, batch number, net content, production date, the number of this standard, and the "flammable liquid" mark specified in GB190


    7.


    7.


    7.


    7.


    Industrial cyclohexanol should be handled with care during transportation to prevent violent impact


    7.


    Cyclohexanol for industrial use should be stored in a ventilated, cool and dry warehouse, protected from direct sunlight, away from fire and heat sources, and keep the container sealed; it should be stored separately from oxidants


    7.


    Under the conditions of packaging, storage and transportation in accordance with this standard, the shelf life of cyclohexanol for industrial use is at least 3 months from the date of leaving the factory


    8 Security

    8.
    1 Important data

    The boiling point of cyclohexanol is 161.
    1°C; the freezing point is 25.
    15°C; the flash point is 67.
    2°C (open cup); cyclohexanol is a flammable liquid with medium flash point, which can easily cause explosion when exposed to open flames, high heat and strong oxidants.
    This produces explosive peroxides
    .
    Cyclohexanol has a pungent odor and is irritating to eyes, mucous membranes or skin, and there is a risk of burns
    .

    8.
    2 First aid measures

    Skin contact: Take off contaminated clothes and wash skin with plenty of water
    .
    Eye contact: rinse with plenty of water for a few minutes (remove contact lenses if possible), and seek medical attention
    .
    Inhalation: Leave the scene quickly to a place with fresh air, keep the respiratory tract unobstructed, give oxygen, artificial respiration, and seek medical attention if necessary
    .
    Ingestion: Rinse mouth, drink plenty of water, and seek medical attention
    .

    8.
    3 Fire fighting methods

    Spray water to cool the container, and move the container from the fire scene to an open place when feasible
    .
    If the container in the fire scene changes color or produces sound from the safety relief device, personnel must immediately evacuate the scene
    .
    The fire extinguishing agent is alcohol-resistant foam, dry powder, carbon dioxide and sand
    .

    8.
    4 Leakage disposal

    In the event of a leak, quickly evacuate personnel from the leaked contaminated area to a safe area, and isolate them, strictly restrict access
    .
    Cut off the fire source
    .
    It is recommended that emergency response personnel wear self-contained positive pressure breathing apparatus and fire protective clothing, and do not directly touch the leakage
    .
    Cut off the source of leakage as much as possible to prevent entry into restricted spaces such as sewers and flood drains
    .
    A small amount of leakage should be absorbed by sand, vermiculite or other inert materials, or it can be scrubbed with an emulsion made of non-combustible dispersant, and the lotion should be diluted and put into the wastewater system
    .
    A large number of leaks should be stored in dikes or pits, covered with foam to reduce vapor disasters, transferred to tank trucks or special collectors with explosion-proof pumps, and recycled or transported to waste disposal sites for disposal
    .

    Related Links: Cyclohexanol for Industrial Use (2)

     

     

    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.