echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Chemicals Industry > Chemical Technology > Determination method of quinolone drug residue analysis technology (4)

    Determination method of quinolone drug residue analysis technology (4)

    • Last Update: 2021-09-19
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com

    (6) Self-ordered ring fluorescence microscopic imaging technique (self-ordered ring fluorescence microscopic imaging technique) The self-assembled ring (SOR) fluorescence microscopic imaging technique uses an inverted fluorescence microscope to deposit an analyte on the ring line.
    The charge-coupled element camera system is used as a microscope image acquisition technology to collect images, convert the image signals into electrical signals and input them into a computer for data reading and image processing, and then apply software to analyze the relevant parameters of the obtained image reading
    .


    It has the advantages of low background interference, low sample consumption, simplicity, speed and no pollution to the environment


    (7) Biosensor method (biosensor)

    1) Molecularly imprinted sensor

    When the template molecule (imprinting molecule) contacts the polymer monomer, multiple points of action will be formed.
    This effect will be remembered through the polymerization process.
    When the template molecule is removed, the polymer will form a spatial configuration with the template molecule.
    Matching holes with multiple points of action, such holes will have selective recognition characteristics for template molecules and their analogs
    .


    Xuan-Anh et al.


    2) Surface plasmon resonance sensor

    Surface Plasmon Resonance (SPR) technology has high sensitivity, simple operation, real-time monitoring of the dynamic process of the reaction, only simple pretreatment of the sample, no labeling, no need to purify various biological components, and low sample consumption , The detection time is short, and it has been widely used in various research fields
    .


    Marchesini et al.


     

     

    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.