2.
1.
8 Linearity range and lower limit of determination
Prepare mixed standard solutions with concentrations of 1.
0 ng/mL, 2.
0 ng/mL, 5.
0 ng/mL, 10.
0 ng/mL, and 50.
0 ng/mL, and perform determination under selected conditions.
The injection volume is 50 uL.
High is plotted against the concentration of each tested component in the standard solution
.
Lincomycin, oleandomycin , erythromycin , tilmicosin , tylosin , clindamycin, spiramycin , guitar ADM , the absolute amount of josamycin in the range of 0.
Table 6-11 Linear equations and correlation coefficients of 9 antibiotics
Under the operating conditions of this method, when 9 antibiotics were added at a level of 1.
0-50μg/kg, the response values were within the linear range of the instrument, and the signal-to-noise ratio S/N of the measured spectra was greater than 5
6.
2.
1.
9 Method recovery and precision
Use beef samples that do not contain 9 kinds of antibiotics for addition recovery and precision experiments.
After adding 1.
0μg/kg, 2.
0μg/kg, 5.
0μg/kg, 10.
0μg/kg different concentration standards to the sample, shake it well to make the standard sample Fully absorb, and then perform extraction, purification, and determination according to this method.
The recovery rate and precision are shown in Table 6-12
.
It can be seen from Table 6-12 that the average recovery rate of this method is between 79.
Table 6-12 The recovery rate and precision experimental data of 9 antibiotics (n=10)