    A.


    Due to its toxicity, the content of residual internal acrylonitrile monomer must be minimized in acrylonitrile polymer.


    A.


    For reagent purity and safety precautions, see Chapter 4 of this standard


    A.


    A.


    A.


    A.


    A.


    A.


    Equipped with a hot nitrogen detector, the injection port is heated or with an automatic gas phase sampling system


    The gas chromatography test conditions are:

    Chromatographic column: a stainless steel column with a length of 4m and an inner diameter of 2.


    Temperature of sampling plant: 140℃;

    Detector temperature: 140℃;

    Carrier gas: helium;

    The flow rate of the carrier gas: 1.


    Adjust the air flow rate (under 1.


    In order to optimize the signal of the thermionic detector, it should be operated strictly in accordance with the instructions of the instrument manufacturer.


    The recommended automatic sampling conditions are as follows:

    Injector temperature: 140℃;

    Incubator temperature: 70℃;

    Constant temperature cycle: 16h;

    Sampling time; 5s;

    Purge time: 30s;

    Reset interval; 30s;

    A.


    A.
    3.
    3 Bottle cap sealer

    A.
    3.
    4 Micro syringe: 0.
    1uL graduation, 10uL
    .

    A.
    3.
    5 Gas syringe: 1mL (used for manual sampling).

    A.
    3.
    6 Semi-microbalance: precision 0.
    01mg
    .

    Related Links: Determination of Residual Acrylonitrile Monomer Content in Styrene-Acrylonitrile Copolymer Gas Chromatography (2)

     

     

    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.