echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Chemicals Industry > Chemical Technology > Determination of residual amounts of streptomycin, dihydrostreptomycin and kanamycin in milk powder, milk, puffer fish, eel and royal jelly

    Determination of residual amounts of streptomycin, dihydrostreptomycin and kanamycin in milk powder, milk, puffer fish, eel and royal jelly

    • Last Update: 2021-11-05
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com

    4) Selection of eluent

    The solid phase extraction column was rinsed with 10 mL methanol water of different concentrations as the eluent, and the optimal methanol concentration of the eluent was selected.
    The experimental data are shown in Table 3-9
    .

    Table 3-9 The influence of different concentrations of methanol water as eluent on the results

    It can be seen from Table 3-9 that 10 mL of 25% methanol water as eluent can effectively remove impurities and eliminate matrix interference.


    The three antibiotics have the highest response signals


    5) Selection of eluent

    This method uses C 18 chromatographic column, and the retention effect of aminoglycoside drugs on C 18 chromatographic column is not ideal, so add sodium heptane sulfonate as ion pair reagent in constant volume solution to enhance its performance on C 18 chromatographic column.
    Keep, the experimental data is shown in Table 3-10
    .

    Table 3-10 The effect of different concentrations of sodium heptane sulfonate as a constant volume solution on the results

    As a weak cation exchange column, the carboxyl column needs to be eluted under acidic conditions.


    It was investigated that 2 mL of formic acid 0.


    Table 3-11 The influence of different concentrations of formic acid 0.
    01mol/L sodium heptane sulfonate as eluent on the results

    It can be seen from Table 3-10 and Table 3-11 that 2mL 4% formic acid 0.
    01mol/L sodium heptanesulfonate aqueous solution is used as the eluent, and the recovery rate of the three antibiotics is the highest, and 2mL 4% formic acid 0.
    01mol/L heptane The sodium alkane sulfonate aqueous solution can completely elute the analyte from the carboxyl column, and it can be directly passed through the membrane for testing without concentration
    .

    (2) Selection of measurement conditions

    1) Selection of liquid chromatography conditions

    This method selects ZORBAX SB-C 18 (3.
    5um, 150 mm×2.
    1 mm), Atlantis-C 18 (3um, 150 mm×2.
    1 mm) and Symmetry-C 18 (3um, 150mm×2.
    1mm) three liquid phase analysis The column was tested, and the detection sensitivity and separation effect of the three columns streptomycin , dihydrostreptomycin and kanamycin were compared.
    As a result, it was found that the Atlantis-C 18 analytical column had better sensitivity and resolution
    .


    Therefore, this column was selected as the analytical column


    2) Selection of mass spectrometry conditions

    Take the standard 10μg/mL of streptomycin, dihydrostreptomycin and kanamycin, and inject the standard solution into the ion source at a flow rate of 10uL/min to find qualitative and quantitative ion pairs.


    Related links: Selection of analytical conditions for determination of residues of streptomycin, dihydrostreptomycin and kanamycin in milk powder, milk, puffer fish, eel and royal jelly

     

     

    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.