echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Active Ingredient News > Drugs Articles > Diaper Water Absorption Tester Shanghai Huitao

    Diaper Water Absorption Tester Shanghai Huitao

    • Last Update: 2022-09-07
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    HT-018CC-5 Diaper Permeability Tester Adult Diaper Permeability Tester The instrument is used to measure the absorption rate, rewet performance and penetration performance of diapers and other products
    .

    Compliant with standards: GB/T28004.
    1, GB/T28004.
    2-2021,
    etc.

    Product features: 1.
    The test solution used in the test adopts the peristaltic pump to control the liquid addition method to ensure the stability and repeatability of the liquid addition, and the liquid addition accuracy can reach ±1%
    .

    2.
    The test solution (physiological saline) is heated by a water bath and stored in a glass tank, which will not have any effect on the performance of the test solution
    .

    3.
    Children's diaper test sample fixture: 3 U-shaped bases, 3 sample holders, 3 standard liquid filling modules, 3 standard pressure modules
    .

    4.
    Adult diaper sample fixture: 1 U-shaped base, 2 standard liquid filling modules, 2 standard pressure modules
    .

    5.
    All sample fixtures are made of PA66 material by 3D printing, which has strong impact resistance, corrosion resistance and high temperature resistance
    .

    6.
    The whole machine adopts the desktop structure design, the operation is stable, and the mobile installation is more convenient
    .

    7.
    The main control adopts ST 32-bit MCU, which can be equipped with the Internet of Things function, which is convenient for data access to the customer's ERP system
    .

    8.
    Adopt touch screen control and display, Chinese and English interface menu operation
    .

    Technical parameters: 1.
    Test parameters for children's diapers Size 1.
    1, U-shaped sample base parameters: B1: L:125±1mm W:122±1mmB2: L:136±1mm W:135±1mmB3: L:154±1mm W: 152±1mm1.
    2, standard dosing module parameters: M1: L:100±1mm W:80±1mmM2: L:108±1mm W:85±1mmM3: L:125±1mm W:95±1mm1.
    3, standard Test pressure module: Y1: L:100±1mm W:80±1mmY2: L:108±1mm W:85±1mmY3: L:125±1mm W:95±1mm2, adult diaper test parameter size 2.
    1, U-shaped test Sample base parameters: L: 319 ± 1mm ​​W: 200 ± 1mm2.
    2, standard dosing module parameters: M1: L: 170 ± 1mm ​​W: 70 ± 1mm ​​M2: L: 170 ± 1mm ​​W: 95 ± 1mm2.
    3, standard Test pressurization module: Y1: L:170±1mm W:70±1mmY2: L:170±1mm W:95±1mm3, pressurization pressure: 2.
    0±0.
    2 KPa, 4.
    0±0.
    2 KPa4, liquid flow rate: 480±5 ml/min (children), 750±5ml/min (adult) 5.
    Timing range: 0.
    00 ~ 9999.
    99 s6, test solution heating range: room temperature +5℃~50℃7, power supply: AC220V, 200W, 50Hz8, size L× W×H: 320mm×220mm×500mm Penetration Test Method A.
    1 Overview Place the sample on the curved sample base lined with absorbent paper, and place the standard test liquid addition module on the absorbing area of ​​the sample surface.
    Under a certain pressure, the liquid filling device injects a certain volume of normal saline into the standard test liquid addition module, and the automatic timing device records the time from the start of adding liquid to the sample completely absorbing the normal saline
    .

    Each sample was added twice, and the absorption speed of the sample was represented by the two absorption times respectively
    .

    After the second liquid addition is completed, take out the standard test liquid addition module, place a certain number of layers of absorbent paper on the surface of the sample, and then put it into the standard test pressurization module, and pressurize it under a certain pressure for a specified time to test.
    The mass increase of the absorbent paper on the top of the sample represents the rewet amount of the small sample, and the mass increase of the absorbent paper at the bottom of the sample represents the leakage of the sample
    .

    A.
    2 Instruments and materials A.
    2.
    1 Absorption performance tester for diapers A.
    2.
    1.
    1 Instrument composition The absorption performance tester for diapers consists of a curved sample base, a sample holder, a standard test module, a mobile pressure device, a liquid storage device and Automatic dosing device, automatic timing device and other components
    .

    A.
    2.
    1.
    2 Arc-shaped sample base The arc-shaped sample base is used to place absorbent paper, sample holder, sample and standard test module during the test.
    The schematic diagram is shown in Figure A.
    lo Description: L 319 mm; W 200 mm
    .

    Figure A.
    1 Schematic diagram of the arc-shaped sample base A.
    2.
    1.
    3 Standard test module The standard test module is divided into two types: the standard test liquid addition module and the standard test pressurization module.
    The standard test liquid addition module is divided into M1, M2 according to different specifications Two models, the standard test pressurization module is divided into two types: Y1 and Y2 according to different specifications
    .

    The schematic diagram of the standard test liquid addition module is shown in Figure A.
    2, and the schematic diagram of the standard test liquid addition module is shown in Figure A.
    3
    .

    There is a timing unit at the bottom of the standard test liquid addition module.
    The distance between the timing unit and the bottom of the standard test liquid addition module is (4.
    2±0.
    2) mm, and the front part of the module is set up: there is an arc-shaped concave absorption area, in the absorption area There is a liquid outlet in the lower part of the inner part.
    The straight line distance between the liquid outlet and the bottom of the arc of the standard test liquid addition module is (58.
    0 ± 0.
    5) mm.
    There is a groove with a gradual width in the middle of the bottom of the test liquid addition module.
    The maximum width of the groove is (8.
    0±0.
    2) mm, and it is connected to the absorption area at the same time, and there are raised structures on both sides of the groove
    .

    W (70 + l)mm(Ml), (95±1) mm (M2); L (170±l)mm(Ml).
    (170±l)mm(M2) o Figure A.
    2 Standard Test Addition Schematic description of the module: W (70 + l)mm(Yl), (95±l)mm(Y2); L ——(170 + l)mm(Yl).
    (170±l)mm(Y2)o Figure A .
    3 Schematic diagram of standard test pressurization module A.
    2.
    1.
    4 Mobile pressurization device The mobile pressurization device can provide constant pressure of (2.
    0±0.
    2) kPa, (4.
    0±0.
    2) kPa
    .

    A.
    2.
    1.
    5 Liquid storage device and automatic liquid addition device The liquid storage device is used to store the test solution.
    The deviation of the liquid addition amount of the automatic liquid addition device is ±2 mL, and the liquid addition flow rate is (720 ± 15) mL/mm
    .

    A.
    2.
    1.
    6 Automatic timing device The automatic timing device consists of a timing unit, a timing control part, etc.
    , and is used to automatically record the test time with a resolution of 0.
    01 s
    .

    A.
    2.
    2 Physiological saline 0.
    9% NaCl solution, (36±1)°C
    .

    A.
    2.
    3 Quantitative (145 + 5) g/m2 of absorbent paper, the water absorption is greater than 480%, and the water absorption is determined according to GB/T 24218.
    6
    .

    A.
    2.
    4 A small amount of food coloring
    .

    A.
    2.
    5 The sensitivity of the electronic balance is 0.
    01 g
    .

    A.
    3 Samples Take 5 samples for each sample, and the samples are taken from at least two sales packages
    .

    During the test, hands should not touch the test area of ​​the specimen
    .

    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.