Shanghai Dongxuan Instrument MJ-150F-I mold culture box is suitable for environmental protection, health and epidemic prevention, drug testing, agricultural and animal husbandry, aquaculture and other scientific research, institutions, production departments.
is a special thermostat device for water body analysis and BOD determination, culture, preservation, plant cultivation and breeding experiments of bacteria, mold and microorganisms.
a device wants to have a long service life, can not be separated from the correct maintenance methods.
, do you know how the MJ-150F-I mold incubator is maintained? Below, dongtou instrument to answer you know MJ-150F-I mold incubator how to maintain this question: 1. Culture box in handling, prohibited upside down or more than 45 degrees tilt.
2. After the landing of this equipment, if the ground is uneven should be flat, the equipment should be left around more than 30 cm of space.
use of the equipment at ambient temperatures above 30 degrees C, it is recommended to improve the environmental conditions appropriately (e.g., adding ventilation behind the equipment or transferring the equipment to an environment with air conditioning facilities) to prevent the temperature from losing control due to the compressor overheating.
3. When the equipment is in normal operation, the box load should not be over-crowded, should not affect the air circulation inside the box to ensure uniform temperature inside the box.
4. The equipment shall be kept away from the source of electromagnetic interference and shall be effectively grounded on the ground of the equipment.
5. When the temperature of the incubator studio is close to the set temperature, the heating light is suddenly dim, repeated many times, is a normal phenomenon.
general, the temperature in the work room enters a constant temperature state about 30 minutes after the measured temperature reaches the controlled temperature.
6. If the equipment in the refrigeration state for a period of continuous operation for a period of time, the cooling effect is not ideal (slow cooling or the production of static difference), may be caused by the evaporator frost.
at this time to remove the box content, the set temperature will be set to 40 degrees C, timed operation of 200 minutes or so, and then put into normal use 7. box wall guts and equipment surface to often wipe, in order to maintain cleaning, increase the transparency of the glass.
Do not wipe the outer surface with acids, alkalis or other corrosive solutions.
8. Equipment for a long time, should be dialed off the power cord, wipe clean the box of water.
and run regularly (once every three months) for 5 hours, set the temperature at 40 degrees C, and open the door every two hours to release the moisture, after processing, dial off the power plug for storage.
to remove moisture from electrical components and avoid damage to the devices concerned.
9. Maintenance and repair of equipment should be carried out by professionals in order to avoid accidents.
10. Unusual imagination in use, please cut off the power and contact my company in time!
above is the Dongtang instrument to you know MJ-150F-I mold incubator how to maintain? The answer to this question, I Division specializing in the production of drying boxes, incubators, constant temperature and humidity boxes, pharmaceutical boxes, disinfection boxes, sinks and other laboratory equipment, adequate in stock and preferential prices.