Categories
-
Pharmaceutical Intermediates
-
Active Pharmaceutical Ingredients
-
Food Additives
- Industrial Coatings
- Agrochemicals
- Dyes and Pigments
- Surfactant
- Flavors and Fragrances
- Chemical Reagents
- Catalyst and Auxiliary
- Natural Products
- Inorganic Chemistry
-
Organic Chemistry
-
Biochemical Engineering
- Analytical Chemistry
- Cosmetic Ingredient
-
Pharmaceutical Intermediates
Promotion
ECHEMI Mall
Wholesale
Weekly Price
Exhibition
News
-
Trade Service
4.
4.
Alcohol reacts with excess acetylation reagent.
4.
4.
4.
4.
Preparation of aldehyde-free ethanol: 5g aluminum flakes were refluxed in 1000mL neutral anhydrous ethanol for 1h, and then distilled immediately
4.
4.
Weigh 0.
4.
The hydroxyl value X3 (mg KOH/g) is calculated according to formula (3):
In the formula: V 0 -the volume of the potassium hydroxide ethanol standard titration solution consumed in the blank test, mL;
V 3 —The volume of potassium hydroxide ethanol standard titration solution consumed by the titration sample, mL;
c 3 —The concentration of potassium hydroxide ethanol standard titration solution, mol/L;
0.
m—the mass of the sample, g
Take the arithmetic average of two parallel determinations as the result
4.
5.
5 Tolerance
The difference between the two parallel determinations shall not be greater than 3mg KOH/g
.
4.
6 Determination of purity
4.
6.
1 Reagents and materials
4.
6.
1.
1 Carrier gas and auxiliary gas
a.
Carrier gas: nitrogen or helium , with a purity greater than 99.
9%;
b.
Fuel gas: hydrogen, with a purity greater than 99.
7%;
c.
Combustion gas: secondary air purification
.
4.
6.
1.
2 Reagents and materials used when preparing the color harmonic column
a.
Fixative: SE-30+polyethylene glycol-20M;
b.
Carrier: 101 white silanized carrier
.
Granularity 0.
18~0.
25mm (80~60 mesh);
c.
Solvent: chloroform
.
4.
6.
2 Apparatus
4.
6.
2.
1 Gas chromatograph
Detector: hydrogen flame ionization detector
.
4.
6.
2.
2 Column
a.
Column tube: stainless steel tube or glass tube with an inner diameter of 3.
5~4.
0mm and a length of 2m
.
b.
Filling:
Proportioning: Carrier: Fixing solution=100:5 (of which polyethylene glycol-20M is 0.
05%) (mass ratio) Method of applying fixative solution: Weigh 1.
25g methyl silicone SE-30 and 12.
5mg polyethylene Diol-20M is added to a beaker, 100mL of chloroform is added to dissolve, 25g of the loading body, after a little stirring, it is dried under an infrared lamp or naturally dried
.
c.
Filling method: Cover the outlet end of the chromatographic column (the end connected to the detector) with a little glass wool, draw a vacuum from the outlet end, and load about 20g of stationary phase under gentle vibration, fill it evenly and tightly, and use it again The glass wool is plugged
.
d.
Aging of the chromatographic column: Put the filled chromatographic column into the column box of the chromatograph, after checking the air tightness, pass nitrogen, gradually increase the temperature to 210°C, and age at 210°C for more than 8 hours until the baseline is stable
.
4.
6.
2.
3 Sampler: Micro glass syringe
.
4.
6.
2.
4 Chromatographic data processor: recorder or integrator
.