    Failure and repair tips of reverse osmosis pure water equipment

    • Last Update: 2020-06-05
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    , the production of pure water is not up to standard, why?1Check the EFFECT of RO membrane defiltration, whether to reduce or fail2Check the pure water and waste water end of the RO membrane shell for partition or cracks3Check that one end of the RO membrane rubber ring is suitable for size or damage4Check the effectiveness of the post-activated carbonsecond, the daily water consumption does not meet the requirements is the reason
    ?1Check if the calculation is incorrect2Check that the pump pressure is in place (0.6Mpa)3Check that the wastewater valve or waste water scaler is too general 4 Check that the water temperature is too low three, the pipeline interface near the leak is what is the reason? 1 Check that the PE tube head is cut flat 2 Check that the pipe plug is in place 3 Check that the nut is tightened four, pressure bucket water full, but pure water can not flow outof
    1 Pressure barrel air pressure discharge 2 Rear activated carbon is blocked five, the water machine in the process of abnormal noise is why? 1 Check that the reverse stop valve is malfunctioning or aging 2 Check if there is a problem with the quality of the high-pressure pump six, the machine does not work why? 1 Check if there is a power outage and the plug is inserted securely 2 Check that the low-voltage switch wiring plug is falling off or malfunctioning so that the power supply contacts cannot be returned 3 Check that the connectors of each terminal are falling off 4 Check that the water pressure on the tap water is too low to cause the low-pressure switch to not work treatment method: (1) to replace the low-voltage switch (3) the shedding cable seven, high-pressure pump does not stop
    1 The pressure of the high-pressure pump is insufficient and cannot reach the pressure set by the high pressure 2 The reverse stop valve is blocked and no pure water 3 High pressure is not working and cannot jump eight, after the water is full, the machine repeatedly jump
    1 Insufficient raw water pressure 2 The reverse stop valve relieves pressure 3 The high-voltage switch or the level switch is not working 4 The system has the phenomenon of pressure relief , high-pressure pump is working normally, but can not make water
    1 The high-pressure pump loses pressure 2 Inlet solenoid valve has a fault can not enter the water (pure water waste water is not) (whether to reverse) 3 Pre-filter blockage (no pure water waste water or very small wastewater) 4 Reverse stop valve failure (there is waste water without pure water) 5 Automatic flushing solenoid valve failure, can not effectively close (always in the flushing state) 6 The computer box has a fault can not close the recoil solenoid valve (always in a flushing state) 7.RO membrane blockage ten, the pure water flow is not enough
    1 Pre-filter blockage 2 The pressure of the high-pressure pump is insufficient 3.RO membrane blockage 4 The wastewater valve or waste water scaler is too on 5 Post-activated carbon clogging 6 Pressure bucket pressure is insufficient or internal damage 11, high-pressure pump does not start, can not make water
    1 Check if there is a power failure and if the plug is plugged in 2 Check whether the low-voltage switch is not working and cannot be plugged in 3 Check that the water pump and transformer are short-circuited, or that the whole connection is wrong 4 Check whether the high-voltage switch or water level controller is not working and cannot be reset 5 Check the computer box for any problems twelve, high-pressure pump shutdown, but the waste water is not 1 The solenoid valve is not working and cannot effectively cut off water 2 The computer box is faulty and cannot close the solenoid valve (refers to the micro-computer type) 3 Reverse stop valve pressure relief (small wastewater flow)
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.