-
Categories
-
Pharmaceutical Intermediates
-
Active Pharmaceutical Ingredients
-
Food Additives
- Industrial Coatings
- Agrochemicals
- Dyes and Pigments
- Surfactant
- Flavors and Fragrances
- Chemical Reagents
- Catalyst and Auxiliary
- Natural Products
- Inorganic Chemistry
-
Organic Chemistry
-
Biochemical Engineering
- Analytical Chemistry
- Cosmetic Ingredient
-
Pharmaceutical Intermediates
Promotion
ECHEMI Mall
Wholesale
Weekly Price
Exhibition
News
-
Trade Service
HME Heat and Moisture Exchange Filter Evaluation Filtration Performance Salinity Tester Air Compressor 0.
8MPA I, Application: Short-term Air Sodium Chloride Particles Challenge Test Method to evaluate the filtration performance
of respiratory system filters used to filter breathing gas.
This section applies to respiratory filters
for clinical respiratory systems.
This section does not apply to other types of filters, such as filters used to protect vacuum sources or gas sampling lines for the filtration of shrinking gases or for the protection of biological respiratory measurement test equipment
.
Second, in line with the standard: YY/T0753.
1--2009, ISO 23328-1: 2003 three, technical parameters: 1, color 7 inch touch screen control, man-machine dialogue mode, easy
to operate.
2.
The instrument fixture is simple to operate, all stainless steel material, durable
.
3.
Digital automatic pressure regulation, automatic pressure control and real-time stability are adopted, which greatly improves the test efficiency and accuracy
.
4.
It has the function of preventing pressure overshoot and avoiding affecting the test results
.
5.
Humanized operation, reach the set pressure automatic timer, and automatically remind the end of
the time.
6.
Differential pressure meter: precision differential pressure meter, Z small range is 0 hPa~1 hPa (0--1000pa), accuracy is 0.
005 hPa, used to monitor the pressure difference between the two sides of the sample; 7.
Time setting range: 1~999min, resolution: 0.
18, double dust laser particle counter or double light scattering photometer counting particle median particle size of 0.
075 gm + 0.
020 gm9, using aerosol generator 1 set with four nozzles
。 10.
Control system: PLC, 1 set of fixtures, 304 stainless steel fixtures and high temperature resistance 200°-300°; 11.
Precision regulator pressure control: 0-1MPA can be selected according to requirements; 12.
All joints sampling stainless steel tube fittings, anti-leakage function; 13.
High temperature resistant silicone pad seal 2; 14.
High efficiency filter; 15.
A set of electrostatic neutralization; 16.
Flow meter: ±5%
of the actual value of 0-50L/min.
17, air compressor 0.
8MPA, dryer customers self-equipped;