    How to carry out daily maintenance on the capsule filling machine

    • Last Update: 2019-12-05
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    It is very important to use the capsule filling machine correctly, and the daily maintenance of the capsule filling machine is also important So how to carry out the daily maintenance of the capsule filling machine? 1 This equipment is a vibrating machine The fastening condition of screws at all parts shall be checked frequently If it is loose, it shall be tightened in time to prevent failure and damage 2 The plexiglass parts (worktable board and medicine board) shall be protected from direct sunlight and near high temperature, and heavy objects shall not be used The medicine board must be placed vertically or horizontally to avoid deformation and damage 3 The electrical shell and body must be grounded to ensure safety and cut off the power after work. 4 At the end of every day's work, the residual drugs on the machine and in the mold hole shall be cleaned to keep the whole machine clean and sanitary and avoid washing the machine with water If the mould on the machine needs to be cleaned, the fixing screw can be loosened, and then it can be taken down, which is convenient for installation Common faults and maintenance of capsule filling machine 1 The vibration is not ideal, adjust the voltage 2 The spring screw is loose and tightened 3 The capsule shell is arranged in the working platform plate, with the mouth higher or lower Adjust the height of the dislocation plate and the guide rail 4 The capsule shell has too many inverted heads (more than 3%), and the vibrator is not adjusted properly Because the proper voltage is adjusted or the capsule shell size is not up to the specification, the qualified capsule shell is selected 5 The capsule shell can not fall when it is stuck on the platen Replace the capsule shell or adjust the position of the dislocation plate and platen hole 6 The mold cannot be reset in the track, and the compression spring at the back end of the track is stuck or the capsule variant is stuck Reinstall the spring or ejector rod, and push the stick to push the stuck capsule down 7 The guide plate in the mold is worn, which affects the low rate of capsule fitting Replace the new mold or loosen the positioning on both sides, fasten the positioning nails, change the capsule shape or wet, and replace the capsule shell  
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.