    It is very important to use the vacuum drying oven correctly, and the daily maintenance is also important, so how to carry out the maintenance? 1 Check the oil level frequently If it does not meet the requirements, adjust it to meet the requirements When the vacuum pump is running, the oil level shall be up to the center of the oil mark 2 Check the oil quality frequently If the oil is deteriorated, replace it with new oil in time to ensure that the vacuum pump works normally 3 The oil change period shall be considered according to the actual use conditions and whether it can meet the performance requirements, etc., which shall be determined by the user at his discretion General new vacuum pump, when pumping clean and dry gas, it is recommended to change oil once in about 100 hours After no ferrous metal powder can be seen in the oil, the oil change period can be appropriately extended in the future 4 In general, the vacuum pump shall be overhauled after 2000 hours of operation, the aging degree of rubber seal shall be checked, whether the exhaust valve plate is cracked shall be checked, and the dirt deposited on the valve plate and exhaust valve seat shall be cleaned Clean the parts in the whole vacuum pump cavity, such as rotor, rotor, spring, etc It is usually washed with gasoline and dried Clean rubber parts and dry them with dry cloth When cleaning and assembling, handle with care to avoid damage 5 Clean the pipe if possible to ensure the smooth flow of the pipe 6 After reassembly, the test run shall be carried out Generally, it is required to run for 2 hours without air and change the oil for two times Because a certain amount of volatile substances will be left in the vacuum pump during cleaning, and it will be put into normal operation after normal operation 7 Check whether the vacuum pump pipeline and joint are loose Turn the vacuum pump by hand to see if it is flexible 8 Add bearing lubricating oil into the bearing, observe that the oil level should be at the center line of the oil mark, and the lubricating oil should be replaced or supplemented in time 9 Screw out the water plug of the vacuum pump body, and fill the water (or slurry) 10 Close the gate valve, outlet pressure gauge and inlet vacuum gauge of the outlet pipe 11 Jog the motor, and try to see whether the rotation direction of the motor is correct 12 Start the motor When the vacuum pump is in normal operation, open the outlet pressure gauge and the inlet vacuum pump Gradually open the gate valve and check the motor load after the appropriate pressure is displayed 13 Try to control the flow and head of the vacuum pump within the range indicated on the label, so as to ensure that the vacuum pump operates at the high efficiency point, so as to obtain a large energy-saving effect 14 During the operation of vacuum pump, the bearing temperature shall not exceed the ambient temperature of 35C, and the high temperature shall not exceed 80C 15 If any abnormal sound is found in the vacuum pump, stop the pump immediately to check the cause 16 To stop using the vacuum pump, first close the gate valve and pressure gauge, and then stop the motor 17 In the first month of operation, the vacuum pump changes the lubricating oil after 100 hours, and then every 500 hours 18 The packing gland shall be adjusted frequently to ensure the normal leakage in the packing chamber (it is better to leak out in drops) 19 Check the wear condition of the shaft sleeve regularly, and replace it in time when the wear is large 20 When the vacuum pump is used in the cold winter season, it is necessary to unscrew the drain plug at the lower part of the pump body to drain the medium after the pump is stopped Prevent frost cracking 21 If the vacuum pump is out of service for a long time, it is necessary to disassemble the pump completely, dry the water, coat the rotating part and the joint with grease and install them, and keep them properly.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.