1 Scope
1.
Since this standard cannot determine all possible impurities, such as hydrogen, oxygen, carbon monoxide , carbon monoxide , water, oligomers, and alcohol compounds, other test methods are required to fully characterize propylene samples
1.
2 Normative references
The clauses in the following documents have become clauses of this standard after being quoted in this standard
GB/T3393-1993 Industrial Ethylene and Propylene Determination of Trace Hydrogen Gas Chromatography
GB/T3394-1993 Determination of trace carbon monoxide and carbon dioxide in ethylene and propylene for industrial use.
GB/T3396-2002 Industrial Ethylene and Propylene Determination of Trace Oxygen by Electrochemical Method
GB/T3723-1999 General rules for the sampling safety of industrial chemical products (idt ISO 3165:1976)
GB/T3727-2003 Determination of trace water in ethylene and propylene for industrial use
GB/T8170-1987 Numerical Rounding Rules
GB/T9722-1988 Chemical Reagent Gas Chromatography General Rules
GB/T12701-1990 Industrial Ethylene and Propylene Determination of Trace Methanol Gas Chromatographic Method
GB/T13290-1991 Industrial Propylene and Butadiene Liquid Sampling Method
GB/T19186-2003 Determination of oligomer content in propylene for industrial use gas chromatography
3 Method summary
3.
Under the conditions specified in this standard, an appropriate amount of sample is injected into the chromatograph for analysis
3.
Under the conditions specified in this standard, the sample to be tested and the external standard substance are respectively injected into the chromatograph for analysis
4 Reagents and materials
4.
Carrier gas, gas purity ≥99.
4.
Carrier gas or make-up gas, gas purity ≥99.
4.
The required standard reagents are the various hydrocarbons described in 1.
Related Links: Determination of Hydrocarbon Impurities in Industrial Ethylene Gas Chromatography (3)