    1 Scope

    1.


    Since this standard cannot determine all possible impurities, such as hydrogen, oxygen, carbon monoxide , carbon monoxide , water, oligomers, and alcohol compounds, other test methods are required to fully characterize propylene samples


    1.


    2 Normative references

    The clauses in the following documents have become clauses of this standard after being quoted in this standard


    GB/T3393-1993 Industrial Ethylene and Propylene Determination of Trace Hydrogen Gas Chromatography

    GB/T3394-1993 Determination of trace carbon monoxide and carbon dioxide in ethylene and propylene for industrial use.


    GB/T3396-2002 Industrial Ethylene and Propylene Determination of Trace Oxygen by Electrochemical Method

    GB/T3723-1999 General rules for the sampling safety of industrial chemical products (idt ISO 3165:1976)

    GB/T3727-2003 Determination of trace water in ethylene and propylene for industrial use

    GB/T8170-1987 Numerical Rounding Rules

    GB/T9722-1988 Chemical Reagent Gas Chromatography General Rules

    GB/T12701-1990 Industrial Ethylene and Propylene Determination of Trace Methanol Gas Chromatographic Method

    GB/T13290-1991 Industrial Propylene and Butadiene Liquid Sampling Method

    GB/T19186-2003 Determination of oligomer content in propylene for industrial use gas chromatography

    3 Method summary

    3.


    Under the conditions specified in this standard, an appropriate amount of sample is injected into the chromatograph for analysis


    3.


    Under the conditions specified in this standard, the sample to be tested and the external standard substance are respectively injected into the chromatograph for analysis


    4 Reagents and materials

    4.


    Carrier gas, gas purity ≥99.


    4.


    Carrier gas or make-up gas, gas purity ≥99.


    4.


    The required standard reagents are the various hydrocarbons described in 1.


    Related Links: Determination of Hydrocarbon Impurities in Industrial Ethylene Gas Chromatography (3)

     

     

    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.