echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Active Ingredient News > Drugs Articles > Installation steps of pneumatic UPVC / PVC plastic wafer butterfly valve

    Installation steps of pneumatic UPVC / PVC plastic wafer butterfly valve

    • Last Update: 2017-11-08
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    Pneumatic PP wafer butterfly valve is one of the common valve types in the industrial pipeline Zui The pneumatic PP wafer butterfly valve has a relatively small structure It only needs to put the butterfly valve in the middle of the flanges at both ends of the pipeline, and use the stud bolt to pass through the pipeline flange and lock the pneumatic PP wafer butterfly valve to control the fluid medium of the pipeline Pneumatic PP wafer butterfly valve is especially suitable for places with narrow space or short distance between pipes When the butterfly valve is in the fully open position, the thickness of the butterfly plate is the only resistance when the medium flows through the valve body, so the pressure drop generated by the valve is very small, so it has better flow control characteristics I instructions before installation of pneumatic PP wafer butterfly valve: 1 Before installation, use air spray to clean the external objects on the piping, and clean the internal surface of the piping with clean water 2 Carefully check whether the service condition of the valve is consistent with its performance specification; (temperature and pressure) 3 Check whether there are sundries in the valve channel and sealing surface, and remove them in time; 4 Install the valve in time after unpacking, and do not loosen any fastening screws or nuts on the valve at will 5 The pneumatic PP wafer butterfly valve must use special butterfly valve flange 6 The electric butterfly valve can be installed on any angle of pipeline For the convenience of maintenance, it is recommended not to install it upside down 7 During the installation of butterfly valve flange plate, the flange surface and sealing rubber must be aligned, the screws shall be tightened evenly, and the sealing surface must be fitted completely; if the screw is tightened unevenly, the rubber bulge will appear to block the butterfly plate, or the butterfly plate will cause leakage at the valve rod II Installation steps of pneumatic PP wafer butterfly valve: the correct installation of pneumatic PP wafer butterfly valve is related to the sealing degree of butterfly valve and whether it will leak or not, including the safety in working conditions Users should understand the installation process 1 Place the valve between the two pre installed flanges, and pay attention to the alignment of bolt holes 2 Insert the four pairs of bolts and nuts into the flange hole slightly, and tighten the nuts slightly to correct the flatness of the flange surface; 3 Fix the flange on the pipe by spot welding; 4 Remove the valve; 5 Completely weld the flange on the pipe; 6 Install the valve after the weld joint is cold Ensure that the valve has enough moving space in the flange to prevent the valve from being damaged, and ensure that the valve plate has a certain degree of opening; 7 Correct the valve position and tighten four pairs of bolts, (pay attention not to over tighten) 8 Open the valve to ensure that the valve plate can open and close freely, and then slightly open the valve plate; 9 Tighten all nuts in cross balance 10 Reconfirm that the valve can be opened and closed freely Note: make sure that the valve plate does not touch the pipeline The pneumatic UPVC / PVC plastic wafer butterfly valve must be placed horizontally before installation Remember not to bump at will After it is drawn into the installation length during installation, it is not allowed to dismantle the pneumatic PP wafer butterfly valve without special permission in the field pipeline design This is what we need to know before installation At the same time, we also need to know that the pneumatic PP wafer butterfly valve can be installed at any position, but after the pneumatic PP wafer butterfly valve is installed, the butterfly valve needs to be laid along the line, making a bracket for the pneumatic PP wafer butterfly valve, and once the bracket is made, it is strictly prohibited to remove the bracket when it is used.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.