    Constant temperature thawing instrument instructions: 1, open the power switch, the machine into standby state: the machine has set the default value: press the setting key, the red digital tube will flash, then you press (▲) (▼) to change the number of the digital tube, so that you can change the setting temperature time, the instrument only set 30 ° C -42 ° C two temperature values, the setting will become the actual temperature
    in the incubator within a few seconds 。 2, the time setting from 1min-99.
    50min adjustable setting, the instrument set 20min.
    If you need to change the setting value, press the setting key, set the time digital tube flashing and then press (▲) (▼) to change the time you need
    .
    3.
    After the setting is completed, the instrument will automatically return to the position to determine the parameters
    you set.
    4, the instrument preheating for about 30-40 minutes, the temperature display set temperature, put in the thawed product, click the on/off button - 0k
    .
    5, the instrument and equipment manually add water to release water, the left side of the equipment has a water valve, the use of the valve can be used to
    release water.
    Note: 1.
    Usually set the water temperature, can be turned on for a long time, open the swing switch when used, set the frequency, automatically rock, turn off the swing switch when you are finished, save electricity, and reduce mechanical wear
    .
    2.
    Before use, add water to the water level line, do not dry burn, to protect the heating pipe
    .
    As the boot time continues to increase, the water return of the water tank gradually evaporates, please check the water level at any time (add water for water
    ).
    Make sure the machine is running properly
    .
    3.
    Set temperature: Press SET key to set or view the temperature set point
    .
    Press the SET keyway character to start flashing, indicating that the instrument enters the setting state, press △ key to set the value to increase, press △ or ▽ key data will change rapidly, press the SET key again to return to the normal working state The temperature is set and the heating indicator light is on
    .
    4.
    Set in advance: Press the SET key for 3 seconds to enter the inner parameter setting state
    .
    * A parameter that appears and flashes is the advance amount of stopping, the advance quantity parameter should be carefully adjusted, in order to reduce the temperature overshoot, the instrument will cut off the heating in advance when controlling the heating output, and when the temperature falls below the advance amount, it begins to heat, and the output (relay) will not work within the set value and the advance range, so that the number of relay actions can be reduced to extend the service life of
    the relay.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.