echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Coatings News > Paints and Coatings Market > Jiangsu releases detailed requirements for safety and environmental protection of chemical industry! Class 10 shutdown and withdrawal, class 11 shutdown and rectification, class 11 deadline rectification

    Jiangsu releases detailed requirements for safety and environmental protection of chemical industry! Class 10 shutdown and withdrawal, class 11 shutdown and rectification, class 11 deadline rectification

    • Last Update: 2019-06-12
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    Recently, Jiangsu Provincial Leading Group Office of safety and environmental protection improvement of Chemical Industry issued a notice on printing and distributing detailed requirements on safety and environmental protection improvement of chemical industry In the attachment "detailed requirements for safety improvement of chemical industry in Jiangsu Province", it is clearly proposed to shut down and withdraw (10 articles), shut down and rectify (11 articles) and deadline rectification (11 articles) Among them, it is mentioned that the chemical production enterprises or production units that produce and use explosive chemicals in the assessed and confirmed chemical concentration area will be shut down In the list of chemicals with explosive properties listed after the document, there are 16 chemicals including epichlorohydrin and epichlorohydrin Does this mean that the enterprises or devices that produce and use the above-mentioned chemicals with explosive characteristics will be shut down and quit in all the assessed and confirmed chemical concentration areas in Jiangsu Province? The detailed requirements are as follows: (1) close the exit category (10 items) 1 Products, technologies, processes and equipment listed in the obsolete catalogue 2 Engaging in the production and operation of hazardous chemicals without obtaining the safety production, use and operation license in accordance with the law; failing to pass the safety conditions, safety facility design review and safety facility completion acceptance as required for the construction project or in-service device of hazardous chemicals 3 The chemical production plant has been shut down for more than one year for a long time, and there are uncontrollable safety problems in the restart of the plant 4 Chemical production enterprises that are judged as major fire hazards by the fire department and unable to complete the rectification 5 Chemical production enterprises or production devices that produce and use chemicals with explosive characteristics in the chemical concentration area confirmed by the assessment 6 Major production safety accidents or major administrative punishments for more than 3 times in a row of 12 months 7 Chemical production enterprises or production units that fail to carry out intrinsic safety diagnosis and treatment as required or fail to complete rectification after intrinsic safety diagnosis and treatment 8 Highly toxic, inflammable and explosive chemical production enterprises without safe production conditions 9 Chemical production enterprises that constitute the safety distance between the major hazard sources of class I and II hazardous chemicals and important public buildings does not meet the relevant national standards 10 Chemical production enterprises that still do not have the conditions for safe production after the shutdown and rectification (2) Stop production rectification (Article 11) 1 The devices involved in the key supervision of hazardous chemical process have not realized the automatic control, the system has not realized the emergency stop function, and the automatic control system and emergency stop system of the equipment have not been put into use Two The high and low liquid level alarm is not set in the storage tank area of hazardous chemicals according to the relevant regulations, and the ultra-high liquid level automatic interlock is not used to close the tank feeding valve and the ultra-low liquid level automatic interlock is not used to stop the material transportation measures; the emergency cut-off function is not implemented in the tank area of hazardous chemicals that constitute the first and second level major hazard sources; the first and second level of toxic gas, liquefied gas and highly toxic liquid are involved There is no independent safety instrument system in the tank farm of hazardous chemicals with major hazard sources Three The side of the control room or cabinet room facing the device with fire and explosion hazards does not meet the requirements of national standards on fire and explosion protection; no regional control room or central control room is set for the production device involving nitrification hazardous chemical process; office room, operation room, fixed operation post or rest room are set in class A and class B fire hazard devices; class A and class B fire hazard warehouse and office Public rooms and rest rooms are adjacent to each other, or there are offices and rest rooms in the warehouse 4 The places involving the leakage of combustible and toxic and harmful gases are not equipped with detection and alarm devices according to the national standards, and the alarm signals are not sent to the control room or operation room; the explosion-proof electrical equipment is not installed and used in the explosion-proof dangerous places according to the national standards 5 The fire prevention distance and external safety protection distance between the enterprise and surrounding residential areas and important public buildings, railways, expressways do not meet the requirements of laws, regulations, standards and specifications 6 The source of process technology is unknown, and the proof of process safety and reliability cannot be provided; the chemical process used for the first time in China has not passed the safety and reliability demonstration organized by the relevant departments of the provincial people's government; the newly developed production process of hazardous chemicals has been directly industrialized without small-scale test, pilot test and industrial test 7 Over temperature, over pressure and other detection instruments, audible and visual alarm, safety interlock devices and other facilities are not set in the parts that may cause fire and explosion on the process unit 8 Before the end of 2019, the enterprise has not established an integrated information management system including major hazard monitoring information, combustible and toxic gas detection and alarm information, enterprise safety risk zoning information, on-the-job information of production personnel, and enterprise production process management information 9 The enterprise has not formulated the work system of safety risk study and commitment announcement; has not designated a special person to be responsible for the work of safety risk study and assessment; has not established the safety risk study and assessment and risk management control system for all employees, all posts and all processes of the enterprise; has not set up a special section to publicize the contents of the enterprise safety commitment announcement 10 Universal pipeline filling system is not used for filling flammable, explosive, toxic and harmful liquefied gases such as liquefied hydrocarbon, liquid ammonia and liquid chlorine 11 The spherical tanks of propylene, propane, mixed carbon IV, raffinated carbon IV, liquefied petroleum gas and full pressure liquefied hydrocarbon tanks are not equipped with water injection measures according to the national standards (3) Rectification within a time limit (Article 11): 1 The actual controller does not act as the legal representative; the main person in charge does not have more than 3 years of experience in the chemical industry or has no college degree or above No one of the chemical enterprise's main principals and principals in charge of safety and production has a college degree or above in national education and chemical industry or a technical title of senior engineer in chemical industry; the appointment (change) of the chemical enterprise's main principals, technical principals and safety principals has not been reviewed by the professional ability of the local emergency management department 2 The main principals, technical principals, safety principals and full-time safety management personnel of chemical enterprises have not passed the professional ability training and assessment; the new and transferred employees have not passed the training and assessment as required 3 Operators engaged in hazardous operation fail to meet the basic working conditions; special operators fail to pass the training and assessment of professional ability and obtain the qualification certificate for special operation; personnel engaged in special equipment operation and management fail to obtain the corresponding qualification certificate for special equipment operators 4 The number of full-time safety production management personnel is less than 2% of the total number of employees specified in the regulations of Jiangsu Province on safety production The proportion of Registered Safety Engineer less than 15% of full-time safety production management personnel (at least 1 person for full-time safety management personnel less than 7) 5 Safety production responsibility system covering all departments and personnel has not been established; safety production rules and regulations and operation procedures have not been formulated and revised in time 6 The chemical production enterprises involved in major hazard sources of hazardous chemicals, hazardous chemical processes or production and use of chemicals with explosive characteristics have not reached the level II standardization 7 The pipeline involving highly toxic gases such as phosgene and chlorine and hydrogen sulfide gas passes through public areas except the plant area (including chemical industry park and Industrial Park) 8 The regional overhead power line crosses the production area and does not meet the requirements of national standards 9 The emergency rescue materials are not in conformity with the requirements for emergency rescue materials of hazardous chemical units 10 Fine chemical enterprises did not carry out response safety risk assessment according to the requirements of normative documents 11 The chemical production unit is not equipped with dual power supply according to the requirements of national standards, and the automatic control system is not equipped with uninterruptible power supply Explanation of terms (1) chemicals with explosive properties refer to ethylene oxide, propylene oxide, epichlorohydrin, peroxyacetic acid, methyl ethyl ketone peroxide, benzoyl peroxide, nitrocellulose, guanidine nitrate, tert butyl peroxybenzoate, nitroguanidine, N, n '- dinitrogenpentamethylenetetramine and 2, which are listed in the list of key regulated hazardous chemicals, 16 chemicals including 2 '- azodiisobutyronitrile, azodiisobutyronitrile, nitroglycerin, nitrobenzene, ammonium nitrate, etc (2) Major administrative punishments refer to the serious illegal activities of production safety, which are ordered to stop production and business for rectification, to stop production and business, to stop construction, to stop construction, to revoke - 7 - relevant licenses, to revoke relevant professional qualifications or post certificates, to impose a fine of more than 50000 yuan, to confiscate illegal income, to confiscate the value of illegally mined coal products or mining equipment Administrative penalty of more than ten thousand yuan (3) The actual controller refers to the person who, though not a shareholder of the company, can actually control the company's behavior through investment relations, agreements or other arrangements (4) The regional overhead power line refers to the overhead power line whose voltage level is generally above 35kV.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.