    Maintenance method of biochemical incubator

    • Last Update: 2014-07-15
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    Maintenance methods: 1 The biochemical incubator should be installed in the place with quiet air and small temperature change as far as possible The three pin plug should be used and the socket should be properly grounded 2 Before opening the biochemical incubator, you should be fully familiar with and understand the instructions of the supporting instruments and meters, and master the correct use methods 3 it is strictly prohibited to contain volatile chemical solvents Explosives and flammable gases are placed in the box Flammable sprays should not be used near the incubator, so as to avoid the ignition of electric sparks 4 Always pay attention to whether there is air leakage in the air circuit 5 The biochemical incubator has the function of breakpoint protection and about one and a half minutes delay The compressor will be started again after shutdown for about one and a half minutes 6 To ensure the effective heat dissipation of the condenser, the distance between the condenser and the wall is greater than 100mm There should be a gap of 50mm on the side of the box, and there should be at least 300 mm space on the top of the box 7 When carrying, repairing and maintaining the biochemical incubator, avoid collision, shaking and vibration; Zui has a high inclination of less than 45 ° 8 Stop using, turn off the main power key and the power switch at the back of the equipment, and at the same time, avoid opening the door frequently to keep the temperature stable and prevent dust and dirt from entering 9 The inside and outside of the box shall be kept clean every day, and shall be cleaned after each use If it is not used for a long time, the plastic dust cover shall be covered and placed in the dry room At the same time, the inner tank of the box wall and the surface of the equipment shall be wiped frequently to keep clean and increase the transparency of the glass Do not wipe the outer surface with acid, alkali or other corrosive solution 10 After the training, turn the power switch to "0" If you don't take out the items immediately, please don't open the door The above 10 points are a summary of the safe operation of the biochemical incubator In addition, we should remind you that it is not suitable to use the biochemical incubator in abnormal environment such as high voltage, high current and strong magnetic field, so as to avoid interference, damage and danger When cleaning the biochemical incubator, wipe the inner wall of the incubator with gauze soaked in alcohol for sterilization and disinfection, and then wipe the alcohol with dry gauze If you do not use the equipment for a long time, please unplug the power supply and do the same Good operation, fault and abnormal record of each instrument used, timely repair in case of any problem Shangyu Star Instrument Equipment Co., Ltd is located in Daoxu Town, Shangyu District, Shaoxing City, Zhejiang Province It is an enterprise integrating production, product development, processing and trade The company's main products: drying box series, incubator series, laboratory muffle furnace series, distiller series, as well as clean workbench, air shower room, ventilation cabinet, biosafety cabinet and other complete sets of purification equipment The company has a strong technical research and development team, a strong after-sales service system, is the leading manufacturer of complete set of laboratory equipment in China, welcome customers to buy.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.