    Operation specification of transfer window

    • Last Update: 2017-11-28
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    Transfer window operation specification transfer window operation specification 1 The purpose of transfer window operation specification is to strengthen the use of transfer window in animal room of the company and ensure the operation specification to avoid pollution This system is hereby formulated 2 The scope is applicable to all personnel working in the clean animal room of the company 3 Content 3.1 all items that can be contained in the transfer window and sterilized by UV, such as materials, recording paper, recording pen, instrument equipment and accessories, cleaning supplies, etc., must pass through the transfer window before entering or leaving the SPF animal area and be sterilized according to the specified procedures 3.2 during the use of the transfer window, it is forbidden to open the inner door and the outer door at the same time under any circumstances 3.3 after using the delivery window every day, spray or wipe the delivery window with disinfectant for disinfection 3.4 for each use of the transfer window, the use record of the transfer window and the use record of the ultraviolet lamp shall be filled in 3.5 the service hours of ultraviolet lamp of transfer window are about 4000 hours, which shall be replaced in time 3.6 procedures for materials entering and leaving SPF animal area: 3.6.1 remove the outer packaging of materials that can be removed in the cleaning room, spray or wipe the incoming materials with disinfectant; spray or wipe the outer packaging with disinfectant if the outer packaging cannot be removed, affix labels, and indicate the product name, batch number and quantity 3.6.2 open the side door outside the transfer window (the inner door is closed), put in the materials, and close the outer door Turn on the UV lamp and irradiate for 15-30 minutes 3.6.3 after 15-30 minutes of irradiation, open the inner side door of the transfer window (the outer door is closed), take out the materials, close the inner door and remove the materials 3.6.4 outgoing items from SPF animal area: Contrary to the entry procedure 3.7 procedures for entry and exit of test records, instruments, equipment parts and other items in and out of the clean area: 3.7.1 remove the outer packaging of materials in the washing and elimination room; wipe the materials that cannot be removed with the outer packaging with a rag, label them, and indicate the product name, batch number and quantity 3.7.2 open the side door outside the transfer window (the inner door is closed), put in the materials, and close the outer door Turn on the UV lamp and irradiate for 15-30 minutes 3.7.3 after 15-30 minutes of irradiation, open the inner side door of the transfer window (the outer door is closed), take out the materials, close the inner door and remove the materials 3.7.4 outgoing items from SPF animal area: Contrary to the entry procedure 3.8 precautions 3.8.1 * generally, items that can't withstand high temperature, high pressure and disinfectant immersion are introduced from the transfer window 3.8.2 when there is no item to be delivered, ensure that the doors on both sides of the delivery window are always closed 3.8.3 clean the transfer window before going to work every day, and wipe the inside and outside with disinfectant 3.8.4 non professionals shall not set up procedures for transfer window    
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.