    Precautions for operation of liquid filling and capping machine

    • Last Update: 2017-11-01
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    Operation steps of the liquid filling and capping machine: 1 Connect the external power supply and preheat the power supply for several minutes; connect the external air supply, adjust the air supply pressure, pull up the pressure regulating knob, and rotate clockwise to observe the indicator It is required to check the air leakage at the joints of all components within the range of 0.4-0.6mpa to eliminate the air leakage After the adjustment, press the pressure regulating knob to reset 2 Confirm that there is a bucket in the barrel dividing station and a cover in the upper cover station; 3 Confirm that there is no abnormality in each station; 4 Open the feeding valve of the main pipe; 5 Press the "automatic operation" button, and the machine will enter the automatic working state; 6 When the safety door is opened, the machine will pause, and the machine will automatically run when the safety door is closed 7 Before the machine stops working, the materials in the pipeline must be drained to prevent the materials from fermenting or accumulating in the pipeline, which will affect the normal operation of the next start-up Precautions for the use of the liquid filling and capping machine: 1 Observe the moisture filter and oil mist filter of the pneumatic combined two parts before going to work every day If there is too much water, it should be removed in time, and if the oil level is not enough, it should be refueled in time; 2 Patrol and observe the mechanical parts frequently during production to see whether the rotation and lifting are normal, whether there is abnormality, and whether the screws are loose 3 Check the ground wire of the equipment frequently, and make sure the contact is reliable; 4 Clean the scale platform frequently; 5 Check whether there is air leakage in the pneumatic pipeline and whether the air pipe is broken; 6 Replace the lubricating oil (grease) of the reducer motor every year, check the chain tightness and adjust the tension in time; 7 If it is stopped for a long time, empty the materials in the pipeline 8 Do a good job in cleaning and sanitation, keep the surface of the machine clean, regularly remove the accumulated materials on the scale body, and pay attention to keep the cleaning in the electric control cabinet; 9 The sensor is a high-precision, high sealing and high-sensitivity device, which is strictly prohibited to impact and overload, and it is not allowed to contact during the working process, and it is not allowed to disassemble if it is not required for repair.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Related Articles

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.