    [Detection principle]

    After rapid extraction of the melamine in the sample for about 5 minutes, it reacts with the amine salt precipitation reagent to form a relatively stable suspension.



    [Kit configuration]

    Test solution A, test solution B, 5mL centrifuge tube, 3mL disposable straw, syringe, closed microporous membrane, turbidity tube, rice-shaped turbidity tablet, 100mg/kg melamine control solution


    [Operation method]

    (1) Detection of milk and yogurt Take 1mL of 100mg/kg melamine control solution, dilute it to 10mL with milk that does not contain melamine components, take 2.


    Use a syringe with a needle to take about 2 mL of the sample supernatant, replace the needle with the closed microporous membrane, and inject it into the turbidity tube.


    After 5 minutes, observe from top to bottom and from the side.


    (2) Milk powder detection Take 1mL of 100mg/kg melamine control solution, dilute to 10mL with distilled water or purified water, take 0.


    Take another 5mL centrifuge tube and add 0.


    (3) Feed detection Take 1g of the sample into the turbidimetric tube, add 2mL A test solution, add 2mL purified water, cover and shake vigorously for more than 20 times, and leave it for more than 3 minutes


    Use a syringe with a needle to take more than 2 mL of the sample supernatant, replace the needle with the closed microporous membrane, and distribute the liquid evenly into two clean turbidity tubes.


    [Precautions]

    (1) The purpose of adding "milk or milk powder that is known to be free of melamine components" is to make the matrix of the turbidity liquid the same and to improve the sensitivity of detection


    (2) The test should be repeated when a positive result is found, and chromatography should be used for accurate quantification


     

     

    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.