    5.
    2.
    6.
    9 Method recovery and precision

    Use samples that do not contain 5 cephalosporins to perform addition recovery and precision experiments.
    After adding 4 different levels of 5 cephalosporin standards at 2-100μg/kg (LOD~10 LOD) to the sample , shake well to make The standard substance and the sample are fully absorbed, and then extracted and purified according to this method, and measured with a high performance liquid chromatography-tandem mass spectrometer.
    The recovery rate and precision are shown in Table 5-46
    .


    It can be seen from Table 5-46 that the recovery data of this method is between 91.


    Table 5-46 Experimental data of recovery rate of 5 cephalosporins in puffer fish and eels (n=10)

    5.
    2.
    6.
    10 Repeatability and reproducibility

    Under repeatability test conditions, the absolute difference between the two independent test results obtained does not exceed the repeatability limit (r).
    If the difference exceeds the repeatability limit (r), the test results should be discarded and the two individual tests should be completed again.
    Determination
    .


    Under the reproducibility test conditions, the absolute difference between the two independent test results obtained does not exceed the reproducibility limit (R)


    Table 5-47 The content range of 5 cephalosporins and the reproducibility limit and reproducibility limit equation

    Related links: Determination of 5 cephalosporins residues in puffer fish and eels and selection of analysis conditions

     

     

    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.