1 Scope
This standard specifies the cobalt acetate , manganese acetate , hydrobromic test method of mixing catalyst solution
This standard applies to cobalt acetate , manganese acetate , hydrobromic acid analysis of the mixed catalyst solution
2 Normative references
The clauses in the following documents are quoted as clauses of this standard.
GB/T 601 Preparation of Standard Titration Solution for Chemical Reagents
GB/T 602 Preparation of standard solutions for chemical reagent impurity determination (GB/T602-2002, neq ISO 6353-1: 1982, Reagents for chemical analysis Partl: General test methods)
Preparation of preparations and products used in GR/T 603 chemical reagent test methods (GR/T 603-2002, ned ISO 6353-1: 1982, Reagents for chemical analysis---Part 1: General test methods)
GB/T 621 chemical reagent hydrobromic acid
GB/T 6682 Analytical laboratory water specifications and test methods (GB/T6682-1992.
GB/T 8170 Numerical Rounding Rules
HG/T 2032 industrial cobalt acetate
HG/T 2034 industrial manganese acetate
3 Test method
3.
Some test procedures specified by the test method may lead to dangerous situations
3.
Unless otherwise specified, only reagents confirmed to be analytically pure and grade 3 water specified in GB/T6682, standard titration baths used in the analysis, standard solutions for impurity determination, preparations and products are used in the analysis.
3.
Take 100mL laboratory sample in a colorimetric tube and visually inspect it horizontally under room temperature, natural light or fluorescent lamp
3.
3.
In the neutral pyrophosphate solution, the manganese ions (Mn 2+ ) and permanganate ion (of MnO .
4Mn 2+ + of MnO .
Use a potentiometric titrator to titrate with potassium permanganate standard solution.
3.
3.
4.
2.
1 Sodium pyrophosphate (Na 4 P 2 O 7 ·10H 2 O) solution: saturated solution at room temperature
.
3.
4.
2.
2 Hydrochloric acid solution: 1+5
.
3.
4.
2.
3 Standard titration bath solution of potassium permanganate : c(1/5KMnO 4 )=0.
1mol/L
.
Related Links: Typical chromatogram for determination of methylamine aqueous solution