Pure water equipment water supply pressure is unstable reasons Pure water equipment in the process of use, water pressure, temperature, water quality will have an impact on pure water equipment.
these values, they can lead directly to substandard water quality.
Pure water equipment water intake pressure itself will not affect the amount of salt through, but the increase in water pressure to drive reverse osmosis of the net pressure increased, increased water production, while the amount of salt through almost unchanged, increased water production dilutes the salt through the membrane, reduce the salt permeability rate, improve desalination rate.
When the in-water pressure exceeds a certain value, due to the high recovery rate, increase the intensity difference polarization, but also lead to an increase in salt through the amount, offset the increase in water production, so that the desalination rate does not increase.
cause of low water pressure1, water flow rate is not appropriate.
2, system leakage.
3, high-pressure pump inlet water pressure is insufficient or the pump leakage, leakage.
4, precision filter filter dirt blocking.
5, high-pressure pump failure.
of high water pressure 1, high-pressure pump outlet door adjustment is not proper.
2, the pipe between the high-pressure pump and the reverse osmosis is blocked.
3, thick water regulation door closed too tight or blocked, thick water discharge flow is small.
4, the recovery rate is too low.
treatment method: in the case of high pressure of pure water equipment, water valves, line blockages, water regulation and other factors should be checked in a timely manner.
And pure water equipment water pressure is too low when the situation needs to check the above several situations, check the water flow, see if there is leakage, check the precision filter filter, check the high-pressure pump, one by one troubleshooting fault.
In order to ensure the operation safety of pure water equipment and equipment life, in the daily operation process, we have to observe more, more records, and timely contact with after-sales technical personnel, encounter problems to timely troubleshooting and resolution, to avoid unnecessary losses due to equipment failure.
.