    Three methods for calibration of biological microscopes

    • Last Update: 2022-05-02
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com

    Three methods about the calibration of biological microscopes Biological microscopes are widely used in the fields of histology, cytology, parasitology, microbiology, immunology, genetic engineering, and botany
    .

    In order to obtain clear and bright ideal images and satisfactory microscopy results, resolution is an important indicator of observation results
    .

    From a physical point of view, the resolution of biological microscopes is limited by the interference phenomenon of light and the performance of the objective lens used
    .

    Therefore, various optical technical parameters of the biological microscope should be calibrated according to the standards, and quality control should be taken for the items that involve accurate quantitative requirements during the calibration process to ensure the accuracy and reliability of the measurement results
    .

    Biological microscope calibration method 1.
    In terms of appearance, biological microscopes should be marked with information such as name, model, serial number, and manufacturer
    .

    The imaging of the optical system in the entire field of view should be clear, and there should be no shadows or reflected light spots that affect the observation in the field of view.
    The clear area of ​​imaging should be concentric with the field of view
    .

    The movement of each part of the biological microscope should be flexible and stable, without sticking and beating, and the illumination in the field of view should be uniform
    .

    The spectral colors of the left and right systems of the binocular microscope should be basically the same, with no obvious difference between light and dark
    .

      2.
    The fine-tuning handwheel should be flexible and stable, and the tightness should be moderate
    .

    For fine-tuning the interval between the marking lines of the handwheel, measure the starting, middle and end positions of the handwheel
    .

    Before measurement, fix the indicator on the biological microscope with a clamp to ensure that the indicator and the microscope are fastened and firm.
    When fixing the indicator, ensure that the measuring head is in vertical contact with the stage
    .

    Adjust the focusing handwheel of the biological microscope to zero the reading of the indicator
    .

    Rotate the focusing handwheel 10 scales, read the indicated value, and take 1/10 of the indicated value as the measurement result
    .

    The average value of the measurements at the start, middle and end positions is used as the calibration result
    .

      3.
    Adjust the light source to an appropriate position for the magnification error of the objective lens of the biological microscope, install the eyepiece with a graduated scale on one of the sleeves of the biological microscope, place the standard glass scale on the stage, adjust the eyepiece and the standard glass ruler Make the reticle line parallel to the standard glass ruler line to avoid measurement errors
    .

    Adjust the stage so that the zero position of the glass ruler is aligned with one end of the reticle, and then read directly
    .


    The above is the relevant introduction about the calibration method of biological microscope.
    I believe that you will have a corresponding understanding after reading it, and I hope it will be helpful to you.

    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.