    What are the common faults of vertical cleaning machine and how to deal with them?

    • Last Update: 2019-07-08
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    The vertical cleaning machine is suitable for cleaning 10-30ml oral liquid glass bottle according to YY 0056 standard This machine can automatically complete the whole production process from bottle in, ultrasonic rough washing, bottle outer wall fine washing, bottle inner wall fine washing to bottle out The combination of ultrasonic cleaning and water air pressure jet cleaning is a popular cleaning equipment in the world, with high clarity and low broken bottle rate The following is a brief introduction of the common faults and handling methods of vertical cleaning machine, as follows: 1 When the vibrator is degummed, our transducer adopts cementation and screw fastening double assurance skills, which will not present this situation under normal conditions 2 When the ultrasonic vibrator is damped, it can use a megohmmeter to check the plug connected with the transducer, and check the insulation resistance value to judge the basic situation Generally, it is required that the insulation resistance is more than 5 megohm If the insulation resistance value cannot be reached, the transducer is usually damped, and the transducer as a whole (excluding the plastic spraying shell) can be put into the oven to set 100 ℃ for drying for 3 hours, or use the electric blower to remove the moisture until the resistance value stops normally 3 The stainless steel oscillating surface is perforated Generally, the transducer with full load may be perforated in the future 4 The transducer vibrator is ignited and the ceramic material is broken It can be seen by naked eyes It is usually used as an emergency treatment method to disconnect individual damaged vibrator without affecting the normal operation of other vibrator  
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.