    Home > Active Ingredient News > Drugs Articles > What are the protection measures for the short-term shutdown of medical purified water equipment?

    What are the protection measures for the short-term shutdown of medical purified water equipment?

    • Last Update: 2019-12-31
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    Medical purified water equipment will inevitably face the situation of frequent outage During the outage, no matter in the short term or in the long term, we must take some protective measures Some improper treatment will cause the degradation of membrane performance of medical purified water equipment, and this loss can not be recovered The following is a brief introduction to the protection measures for the short-term shutdown of medical purified water equipment: for the short-term shutdown of medical purified water equipment, if the system is less than 15 days, we can use the low-pressure flushing method every 1-3 days to protect the medical purified water equipment It has been proved by practice that if the water temperature is above 20 ℃, the water in the medical purified water equipment will stink and deteriorate when stored for three days, and there will be a large number of bacteria breeding Therefore, I suggest that when the water temperature of medical purified water equipment is higher than 20 ℃, we use low-pressure flushing every 2D or 1D When the water temperature is lower than 20 ℃, we can use low-pressure flushing every 3D After each flushing, we need to close all the inlet and outlet valves on the medical purified water equipment The above-mentioned outage protection of medical purified water equipment is only for short-term outage As long as we do these works well, some unexpected accidents can be avoided next time we run the medical purified water equipment In addition, the editor will also introduce the reasons for the rapid decrease of desalination rate of reverse osmosis membrane of medical purified water equipment.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.