    The prefilled prefilled syringe with injection needle is embedded, consisting of needle, needle tube, needle cap, piston and push rod; needleless can be divided into cone head type and screw head type
    .

    The cone head type consists of a piston, a push rod, a needle tube and a cone head protection cap, and the screw head type consists of a piston, a push rod, a needle tube, a screw head protection cap and a screw head
    .

    In view of the fact that prefilled prefilled syringes can not only be used as inner packaging containers of medical instruments, but also can be used for injection purposes
    .

    The main technical indicators of the pre-filled syringe tester are as follows: whether or not it has obtained the registration certificate for drug packaging materials or medical devices, from the perspective of the final product, the relevant performance indicators and test methods should be specified in the product's technical requirements , for example, thrust, appearance of the syringe (can be incorporated into the appearance of the product), size, luer fitting (for non-luer fittings, the syringe and needle fit must be leak-free), effective volume (or load), syringe Body fit (no gel leaking at the piston or taking water to test), piston fit (core rod not moving due to gravity but staying vertical),
    etc.

    For specific performance indicators and test methods, please refer to GB 15810 or relevant national/industry standards
    .

    The specific performance indicators and test methods of the pre-filled syringe tester for piston sliding, injection needle (needle) rigidity, and piston thrust can refer to GB 15810 or relevant national/industry standards
    .

    The sliding property of the piston of the pre-filled syringe: The sliding property of the piston is a very important target detection technical indicator for detecting the pre-filled syringe, because when we push the piston, the piston and the inner wall of the glass needle tube will have a certain resistance.
    If the force value is too high, the general system will cause this kind of injection difficulty.
    If the force value is too small, the injection will be too fast and too violent, causing some danger
    .

    The Syringe Sliding Performance Tester is mainly used to measure the physical properties of the sliding performance of medical syringes, and is one of the important means to identify medical syringes.
    The main testing instrument is HX15810-C Syringe Sliding Performance Tester
    .
    HX15810-C Syringe Sliding Performance Tester Technical Parameters: Operation Interface: Simplified Chinese/English Test Standard: GB 15810-2019 Disposable Sterile Syringes ISO7886-1: 2017 Disposable Sterile Syringes Test Range: 0.
    1N~100N Error Not more than ±0.
    1N; Test rate: 100mm/min Error range: ±1mm/min; (Test speed can be set by software) Nominal capacity: 0.
    1ml~200ml, all specifications can be input arbitrarily
    .

    Programmable controller: PLC/ARM Touch screen: 7-inch K600+ core/dot matrix 65 colors 800*480 resolution Sensor: high-precision force sensor Force measuring mechanism: built-in printer: on-board needle printer Rigidity test: In the application process of stainless steel needles, it is required to have a certain rigidity to ensure that the steel needles are not easy to bend during use and reduce the occurrence of medical accidents.
    The rigidity tester for medical injection needles (needles) is mainly used to measure the rigidity of medical injection needles.
    The physical characteristics of performance are one of the important means to identify medical injection needles.
    The main testing instruments are GX9626-T medical injection needle tube (needle) rigidity tester
    .

    Using 7-inch color LCD screen, using PLC+ARM editor, Chinese menu display
    .

    Nominal Size, Wall, Span, Set Load, Maximum Deflection, Print Set, Test, Up, Down, Time, Calibration
    .

    GX9626-T Medical Injection Needle Tube (Needle) Rigidity Tester Specifications: Test Standard: GB/T18457-2015 Stainless Steel Needle Tube for Medical Device Manufacturing ISO9626-2016 Requirements and Test Method for Stainless Steel Needle Tube for Medical Device Manufacturing Tube Wall: Normal Wall, Thin Wall , ultra-thin wall, ultra-thin wall four optional; nominal size: 0.
    1 ~ 6.
    5mm (all specifications can be tested); set load: 0.
    01 ~ 120N, accuracy: ± 0.
    001N; loading rate: 1 ± 0.
    1mm /min; Span: 5~50mm, Accuracy: ±0.
    01mm (11 specifications); Deflection test: 0~10mm, Accuracy: ±0.
    001mm; Printing method: 100 times of test data and average deflection value and deviation can be printed each time value
    .

    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.