Medical catheters are more classified according to the function used, which can be divided into: 1.
infusion catheter 2.
hemodialysis catheter 3.
angiographic catheter 4.
Catheter for endovascular interventional therapy 5.
Gastrointestinal catheter 6.
Respiratory tract catheter 7.
Urinary system catheter 8.
Nervous system catheter 9.
Surgical drainage tube and so on
.
Weisha Technology's main testing of the physical properties of catheter leakage is the following testing equipment: (1) catheter vacuum residual leakage tester, (2) drainage system component leakage tester (catheter), (3) pipeline leakage tester, (4) pressure liquid leakage tester (catheter) drainage system or any component leak-free test method 1.
Principle catheter no leakage According to GB/T15812.
1 test, the drainage system or any component should have no leakage under the maximum negative pressure nominally in the production plant
。
2.
Instrument XL0489-C drainage system component leak tester (catheter), fully in line with the standard intelligent manufacturing
.
It is mainly used to determine the physical characteristics of disposable sterile drainage catheter auxiliary devices, and is one of the important means to identify the physical properties of disposable sterile drainage catheter auxiliary devices
.
3.
Reference standard sterile drainage tube can refer to the product standard is YY 0489-2004 "disposable sterile drainage catheter and auxiliary equipment", the standard stipulates that the sterile drainage tube sealability can be detected with reference to the standard GB/T 15812.
1-2005 "Non-vascular catheter Part 1: General performance test method": The drainage system or any component should have no leakage
under the maximum negative pressure of the production plant.
XL0489-C drainage system component leak tester test process: 1.
Install the corresponding fixture, put on the test medical equipment 2.
Set the product specifications, test pressure value setting, hold the time setting, and save the parameters 3.
One key to open the test, real-time display of the test pressure value, hold the time and other data 4.
Observe the test pressure value, whether there are continuous bubbles on the surface of the specimen during the process 5.
After the time is over, the test ends automatically, and the on-board printing immediately produces a report