echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Active Ingredient News > Drugs Articles > You need to know the operation rules of single super clean worktable

    You need to know the operation rules of single super clean worktable

    • Last Update: 2020-02-20
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    You need to know the operating procedures of the single super clean worktable These single super clean worktables are easy to operate, comfortable, efficient, short preparation time, and can be operated after more than 10 minutes of starting, and can be used at any time basically In the factory production, the inoculation workload is very large, and it needs to work for a long time The single person super clean workbench is driven by a three-phase motor to blow air through a super filter consisting of a specially made Microcellular Plastic sheet laminated to form a continuous clean and sterile super clean air laminar flow, the so-called "efficient special air", which removes dust, fungi and bacterial spores larger than 0.3 m The flow rate of super clean air is 24-30m / min, which is enough to prevent the pollution caused by the air nearby Such flow rate will not hinder the use of alcohol lamp or Bunsen lamp to burn and disinfect instruments The staff operate under such aseptic conditions to keep the aseptic materials free from contamination during transfer inoculation However, in case of power failure during operation, materials exposed to unfiltered air will not be immune from pollution At this time, the work should be finished quickly, and marks should be made on the bottle If the material in the bottle is in the proliferation stage, it will not be used for proliferation and transferred to rooting culture in the future If it is a general production material, it can also be discarded because it is extremely rich If it is in the process of rooting, it can be reserved for later planting Operation procedures for single ultra clean bench: 1 For newly installed or long-term unused ultra clean bench, it is necessary to clean the ultra clean bench and surrounding circular mirror with Ultra-static vacuum cleaner or tool without fiber before use, and then sterilize with drug sterilization or ultraviolet sterilization; 2 Unnecessary articles are not allowed to be stored in the operation area to keep the clean air flow in the operation area undisturbed; 3 The operation area is a laminar flow area, so the working position shall not hinder the normal flow of air flow, and the staff shall try to avoid the action of disturbing the air flow; 4 The use temperature in the operation area shall not exceed 60 ℃; 5 When using the table, start it 50 minutes in advance, turn on the UV sterilization lamp at the same time, deal with the microorganism accumulated on the surface area of the operation area, turn off the sterilization lamp and start the fan 30 minutes later; 6 Turn off the sterilization lamp when working, otherwise it will cause harm to human body If lighting is needed, turn on the "lighting" key switch, and the fluorescent lamp will light up; 7 The operator shall wear clean work clothes, work shoes, masks and hats to ensure the cleanness and hygiene of the work area; 8 After the operation, clean the work surface, collect all wastes, turn off the fan and lighting switch, wipe and disinfect with detergent and disinfectant; 9 Turn on the UV lamp of the worktable, and after 30 minutes of irradiation and disinfection, turn off the UV lamp and cut off the power supply If any problem is found in the work, report it to maintenance immediately  
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.