    7.
    1.
    1.
    3 Application examples of Linpor process in Chunliuhe Sewage Treatment Plant

    The Linpor process transformation project of Dalian Chunliuhe Sewage Treatment Plant transformed the aeration tank in the original biochemical system into the German Linpor process
    .

    The original Chunliuhe Sewage Treatment Plant adopts the traditional activated sludge method
    .


    There are 4 groups of biochemical pools, each with a length of 40122m (including water inlet and outlet), a width of 20m, and a depth of 415m


    After the Linpor process is adopted, the 4 corridors of each group of biochemical pools are changed to independent water inlet and outlet
    .


    The improvement in the process of each group of biochemical tanks is that one corridor in each group of aeration tanks is filled with small and porous plastic sponge (Linpor) fillers, and the other three corridors use the Linpor process without fillers


    After the transformation, the design flow rate of the sewage plant is 8×10 4 t/d
    .


    At an average flow rate, the sludge load of the biochemical tank is 0.


    The filling and filtering corridor is controlled by the automatic control system through the water inlet butterfly valve, and its water intake is about twice that of the ordinary corridor, that is, 334m 3 /h
    .


    The GVA microporous aerator made in Germany is adopted.


    7.
    1.
    1.
    4 Application examples in petrochemical wastewater treatment

    The sewage treatment plant of a large-scale refining and chemical integration project has a designed water volume of 600m 3 /h.
    After the sewage is treated, it will be reused as circulating water supplementary water.
    Pure oxygen aeration + Linpor nitrification is used as the main biochemical process.
    The Linpor design inlet and outlet water quality is shown in Table 7-1
    .

    Table 7-1 Linpor designed inlet and outlet water quality unit: mg/L

    The design parameters are as follows: design volume load 0.


    26kgNH 3 -N/(m 3 ·d); effective pool volume 1800m 3 ; filler volume 360m 3 ; domestic traditional nitrification process ammonia nitrogen volume load is mostly 0.


    Related Links: Biological Wastewater Treatment-Linpor Process

     

     

    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.