    1 Sampling method

    1 Sampling method

    Randomly select the recently produced products that have the product quality inspection certificate or other forms of qualified products from the products to be sold


    .


    The sampling base shall be no less than 150 pipes or 150 pipe fittings in the same batch and the same specification


    .


    Priority will be given to the selection of product models and specifications with large production and sales volume of the enterprises under random inspection, and priority will be given to the selection of PVC materials with nominal outer diameters of dn20mm-dn110mm


    .


    Table 1 Sampling Quantity and Requirements

    Random numbers can generally be generated using random number tables, random number dice or playing cards


    .


    2 Inspection basis

    2 Inspection basis

    See Table 2-16 for the basis of the random inspection items and inspection methods


    .


    Table 2 Rigid polyvinyl chloride (PVC-U) pipes for water supply (GB/T 10002.
    1-2006) inspection items

    Table 3 Inspection items of rigid polyvinyl chloride (PVC-U) pipes for drainage (GB/T 5836.
    1-2018)

    Table 4 Rigid Polyvinyl Chloride (PVC-U) Pipe Fittings for Drainage (GB/T5836.
    2-2018) Inspection Items

    Table 5 Inspection items of polypropylene pipes for hot and cold water (GB/T 18742.
    2-2017)

    Table 6 Inspection items of polypropylene pipe fittings for hot and cold water (GB/T 18742.
    3-2017)

    Table 7 Inspection items of polyethylene (PE) pipes for water supply (GB/T 13663.
    2-2018)

    Table 8 Inspection items of polyethylene (PE) pipe fittings for water supply (GB/T 13663.
    3-2018)

    Table 9 Inspection items for insulating electrical bushings for buildings (JG/T 3050-1998)

    Table 10 Inspection items for PVC wire duct (QB/T 1614-2000)

    Table 11 Inspection items of rigid polyvinyl chloride (PVC-U) double-wall corrugated pipe (GB/T 18477.
    1-2007) for buried drainage

    Table 12 Inspection items for buried polyethylene (PE) double-wall corrugated pipes (GB/T 19472.
    1-2004/GB/T 19472.
    1-2019)

    Table 13 Buried polyethylene (PE) winding structural wall pipe (GB/T 19472.
    2-2017) inspection items

    Table 14 Inspection Items of Plastic (PVC-U) Solid Wall Pipe (YD/T 841.
    2-2016) for Underground Communication Pipelines

    Table 15 Inspection items for plastic (PE) solid wall pipes for underground communication pipes (YD/T 841.
    2-2016)

    Table 16 Inspection items for PVC plastic corrugated electrical conduit (QB/T 3631-1999)

    For dated documents, all subsequent amendments (excluding errata content) or revisions do not apply to these rules


    .


    3 Judgment Rules

    3 Judgment Rules

    3.
    1 According to the standard

    GB/T 10002.
    1-2006 "Rigid Polyvinyl Chloride (PVC-U) Pipe for Water Supply"

    GB/T 5836.
    1-2018 "Rigid Polyvinyl Chloride (PVC-U) Pipes for Building Drainage"

    GB/T 5836.
    2-2018 "Rigid Polyvinyl Chloride (PVC-U) Pipe Fittings for Building Drainage"

    GB/T 18742.
    2-2017 "Polypropylene piping systems for hot and cold water - Part 2: Pipes"

    GB/T 18742.
    3-2017 "Polypropylene piping systems for hot and cold water - Part 3: Fittings"

    GB/T 13663.
    2-2018 "Polyethylene (PE) Pipeline System for Water Supply Part 2: Pipe"

    GB/T 13663.
    3-2018 "Polyethylene (PE) Piping System for Water Supply Part 3: Pipe Fittings"

    JG/T 3050-1998 "Insulated electrical bushings and accessories for construction"

    QB/T 1614-2000 "Flame-retardant insulated PVC wire duct and accessories"

    GB/T 18477.
    1-2007 "Rigid Polyvinyl Chloride (PVC-U) Structural Wall Piping System for Buried Drainage - Part 1: Double Wall Corrugated Pipe"

    GB/T 19472.
    1-2004 "Buried Polyethylene (PE) Structural Wall Piping System Part 1: Polyethylene Double Wall Corrugated Pipe"

    GB/T 19472.
    1-2019 "Buried Polyethylene (PE) Structural Wall Piping System Part 1: Polyethylene Double Wall Corrugated Pipe"

    GB/T 19472.
    2-2017 "Buried Polyethylene (PE) Structural Wall Pipe System Part 2: Polyethylene Wound Structural Wall Pipe"

    YD/T 841.
    2-2016 "Plastic Pipe for Underground Communication Pipeline Part 2: Solid Wall Pipe"

    QB/T 3631-1999 "Polyvinyl chloride plastic corrugated wire pipe"

    Relevant laws, administrative regulations, departmental rules, normative documents

    Current effective enterprise standards, group standards, local standards and product quality requirements

    3.
    2 Judgment principle

    After inspection, all the inspected items meet the standard requirements, and it is determined that the products under random inspection are not found to be unqualified; if any one or more of the inspection items are unqualified, it is determined that the products under random inspection are unqualified


    .


    If the quality requirements of the inspected products are higher than the standard requirements of the inspection items in these rules, they should be judged according to the quality requirements of the inspected products


    .


    If the quality requirements of the inspected products are lower than the mandatory standard requirements on which the inspection items are based in these detailed rules, they shall be judged in accordance with the mandatory standard requirements
    .

    If the stated quality requirements of the inspected product are lower than or contain the recommended standard requirements on the basis of the inspection items in these detailed rules, it shall be judged based on the stated quality requirements of the inspected product, but it shall be explained in the remarks of the inspection report
    .

    If the quality requirements of the inspected products lack the mandatory standard requirements on which the inspection items are based in these detailed rules, they shall be judged in accordance with the mandatory standard requirements
    .

    If the quality requirements of the inspected products lack the recommended standard requirements on which the inspection items are based in these detailed rules, the items will not participate in the judgment, but should be explained in the remarks of the inspection report
    .

    Article link: Plastic Machinery Network http://

    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.