echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Coatings News > Paints and Coatings Market > Coating process: construction process of Waterborne Acrylate waterproof coating

    Coating process: construction process of Waterborne Acrylate waterproof coating

    • Last Update: 2020-04-03
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    The key point is: waterborne acrylic waterproof coating is made of elastomeric acrylate emulsion or propylene acrylic copolymer emulsion as the main film forming material, adding dispersant, defoamer and thickening agent Compared with other solvent waterproof coatings, water-based acrylate waterproof coating is non-toxic, safe in construction, no adverse impact on the environment, convenient in operation, and no adverse impact on the health of construction personnel And the construction can be carried out on the slightly humid base course It can be widely used in the waterproof, impervious and moistureproof works of non exposed roofs, toilets and bathrooms and external walls of buildings 1 Construction of Waterborne Acrylate waterproof coating Shenyang steel structure fireproof coating construction expert punde Building Fire Engineering Co., Ltd Recommended introduction: since its establishment, Shenyang punde Construction Fire Engineering Co., Ltd has cultivated a group of professional construction teams with excellent equipment, rich experience and serious responsibility with advanced and scientific management methods and strict engineering quality assurance and after-sales service system It has undertaken a number of fire system installation projects, which has been praised by customers Every idea and special requirement of you will be fully considered by us and fully realized in the construction technology, which will become the cornerstone of our successful long-term development We are looking forward to your invitation, to provide you with quality services and high-quality technical support! All construction coatings have passed ISO9001 Coatings home: waterborne acrylic waterproof coating is made of elastomeric acrylate emulsion or propylene acrylic copolymer emulsion as the main film forming material, adding dispersant, defoamer, thickening agent and other waterproof coatings Compared with other solvent waterproof coatings, water-based acrylate waterproof coating is non-toxic, safe in construction, no adverse impact on the environment, convenient in operation, and no adverse impact on the health of construction personnel And the construction can be carried out on the slightly humid base course It can be widely used in the waterproof, impervious and moistureproof works of non exposed roofs, toilets and bathrooms and external walls of buildings 1 Construction steps and operation methods of water-based acrylate waterproof coating (1) base treatment a) the surface of base course shall be troweled smooth and free of dust, oil, debris and other debris b) In addition to the concave convex, hollowing and void gap, repair and level them to a certain strength c) The internal and external corners shall be made into small round corners with a radius of about 10 mm and moved to flat and smooth corners d) All pipes, sanitary equipment and floor drains connected with the base must be installed firmly, with tight joints and smooth hands No loosening is allowed e) The surface of dry base course, especially brick masonry, shall be treated with water spray, and the free moisture shall be wiped off with dry cloth to improve the adhesion with base course (2) Construction of water-based acrylate waterproof coating the construction tools of water-based acrylate waterproof coating can be rubber or plastic scraper, large-area construction can be fully coated with roller brush, and the root of water pipe and internal and external corners can be brushed with paint a) First brush a primer and dry for more than 4H b) The first coating shall be applied after the primer is dry, and the non-woven fabric shall be uncoiled and pasted, and the second and third coating shall be applied after drying The thickness of each coating is 0.4-0.6mm Each coating construction can only be carried out after the previous coating is dried (4-12h), and the direction of coating and scraping shall be perpendicular to the direction of the previous coating and scraping c) The non-woven fabric must be laid flat, and the joint of the fabric shall be overlapped by 2cm A layer of non-woven fabric must be pasted to strengthen the parts with complex shapes such as floor joint, purchase, wall corner and pipe corner which are easy to cause leakage (3) If the protective layer needs to be made during the construction of the protective layer, the cement mortar protective layer can be made after the fixed line coating is complete and accepted as qualified, or the facing layer can be paved with traditional methods such as facing bricks and mosaics Home of coatings is specialized in coatings, diatom mud, paint coating, coating technology, fire retardant coating news and coating, diatom mud, paint coating, coating technology, fire retardant coating decoration knowledge and decoration renderings,
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.