Artificial climate box works and use notes Artificial climate box is a high-precision constant temperature constant humidity lighting simulation test equipment with refrigeration, heating, lighting control, which can be used for plant culture, breeding test, bacteria, mold, microorganism culture, preservation, BOD determination of water body analysis and other uses of thermostat test.
is the ideal test equipment for scientific research units such as biogenetic engineering, medical treatment, health and epidemic prevention, drug testing, agriculture, animal husbandry and aquatic products.
: The artificial climate box is converted into electrical signals by sensors located in the box, where the actual temperature and humidity sensors are felt by the temperature sensor and humidity sensor.
can be preset light intensity and electrical signals, by microcomputer to control the heater, humidifier, light intensity or cooling compressor work, so as to achieve the desired temperature, humidity and lightness control to achieve the required.
daily use precautions and their maintenance: a) Use artificial climate boxes to be reliably grounded.
if not properly grounded can result in electric shock or fire.
b) Make sure that the power plug is securely plugged into the power board and that it may also cause electric shock, overheating, or equipment failure if the plug is not tight and loose.
c) Do not use it.
unplug the device by not turning off the power switch to avoid overheating and sparking fires.
d) Try to avoid damaging the power cord or using a non-specified power cord.
to avoid damage to equipment or electric shock and fire.
) Do not disconnect or use a long wire in the middle of the power cord.
avoid electric shock or fire due to overheating.
f) Do not unplug the power cord with your hands wet.
, there is a risk of electric shock.
g) Do not change the setting frequently during use to avoid overload caused by frequent compressor start-up, which can affect the life of the equipment.
h) Water tank water is strictly prohibited from using tap water or other unclean water sources.
need to be injected with pure water, distilled water or other ultra-purified water.
or it will cause humidification to fail properly, causing the equipment to malfunction.
i) Be sure to close the inner glass door and then close the box door.
if the inner door is not closed, the device may not function well even if the box door is closed.
when you close the door inside and outside, do not use too much force to cause damage to the door seal.
j) To ensure uniform temperature in the box, always check that the circulating fan in the box is operating properly.
, the items in the box should not be placed too tightly and do not block the fan air out of the air, in order to benefit the air circulation in the box.
k) Do not touch, the collision box temperature, moisture sensor, will cause the temperature or humidity out of control.
l) Do not insert fingers, rods, or other foreign objects into the air feed or infleter.
to avoid damaging or injuring the device by touching a high-speed fan.
m) If there is an abnormal state (burning smell, etc.) the power supply should be switched off immediately to terminate the operation of the device, or the circuit breaker should be used to disconnect the power supply.
in an abnormal state will cause overheating and cause fire or electric shock until the machine is destroyed.
n) Do not make repairs without authorization.
repairs can cause fire or electric shock.
.