How pure steam generatorworks
-
Last Update: 2013-04-08
-
Source: Internet
-
Author: User
Search more information of high quality chemicals, good prices and reliable suppliers, visit
www.echemi.com
How pure steam generatorworks: Raw water is delivered through a feed pump to the side of the pipe that removes the contamination column and the heat exchanger, and the level is controlled by the level meter Industrial steam or heated water enters the heat exchanger and heats the raw water to the evaporation temperature And a strong thermal cycle is formed inside the two bars Pure steam is produced in the evaporator (except the pollution column) The low speed of the steam and the height of the column will remove any small droplets that may be impure under gravity By pneumatically adjusting the opening of the industrial steam intake valve, the pure steam pressure can be maintained constantly at the user-set pressure value, ranging from 0-3bar
Structural Features Pure steam generator consists of two parallel columns: a double-shell seam tube hygienic clean exchanger
In addition to contamination of the column
The equipment is all made of AISI316L stainless steel, and the working surface of the column and exchanger is treated with a standard procedure for acid washing and purification
Washers made of pharmaceutical-grade Teflon
All components are mounted on a sturdy carbon steel stand and can be easily removed and assembled
Mineral cotton insulation, surface covered with AISI304 stainless steel satin polished protective layer
The Working Principle of the S-type pure steam generator S-type pure steam generator workflow is as follows: raw water through the feed pump into the tube of the separator (the two are connected), the level is connected by the level sensor and PLC into control, industrial steam is heated into the shell of the evaporator to the management of the raw material water heating to evaporation temperature, the raw material water becomes steam, this steam in low speed and the high travel of the separator by gravity to separate the small drops back into the water Steam enters the various distribution systems and points of use
The regulation of industrial steam allows the pressure of pure steam to be set according to the procedure for the process of hyper-processing and can be maintained steadily at the pressure value set by the user In the process of evaporation of raw materials, the supply of raw water is controlled by the level, so that the liquid level of raw water is maintained at a normal level, for concentrated water can be set in the procedure intermittent discharge
F-type pure evaporation generator working principle Raw material water in a furnace is heated by industrial steam, into the second-effect preheater by industrial steam condensate water continueto heating; The evaporated raw water, now a secondary steam, continues to spiral up in the evaporator, passing through a soda separation device, as pure steam is exported from the steam outlet Industrial steam condenses into industrial steam condensate as a heating source for the preheater after the evaporator is absorbed by the raw water, and after preheating the raw material water zui, it discharges from the preheater without condensate discharge Trace pure steam is collected by the condensing sampler and heated with cooling water to be cooled into distilled water, and after an online test of conductivity to determine whether pure steam is qualified
The secondary steam converted by the raw water is clean steam, which is separated three times: after the zui first enters the evaporator, it flows down the column tube and evaporates, which is the secondary separation; 80 degrees fold back, impurities in the force of gravity, is separated to the lower part, this is the second separation, the evaporative raw material water, i.e secondary evaporation, continue to circle in the evaporator, to the upper central special separation device, the third separation
In the raw water there is a part of the gas that cannot condense into water, is called non-coagulation gas, this part of the non-condensed gas according to the degree of automation control, in the top of the evaporator is equipped with non-condensed gas continuous discharge device.
This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only.
This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of
the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed
description of the concern or complaint, to
service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content
will be removed immediately.