The constant temperature and humidity test chamber is composed of
multiple systems such as electrical, refrigeration and control systems.
The constant temperature and humidity test chamber needs to be cleaned and maintained during use, which can ensure the normal operation
of the constant temperature and humidity test chamber.
Today Coseid will specifically introduce how to maintain the constant temperature and humidity test chamber for long-term reliable operation, hoping to help users better use the constant temperature and humidity test chamber
.
1.
Insist on setting the temperature between the ambient temperature after the completion of each test constant temperature and humidity test chamber, cut off the power after working for about 30 minutes, and wipe the wall
in the working room.
2, constant temperature and humidity test chamber is generally relatively high, we recommend that it be placed in a more suitable temperature environment, our experience temperature value is 8 °C ~ 23 °C, for laboratories that do not have this condition, must be equipped with appropriate air conditioners or cooling towers
.
3.
Fix cleaning the water tank every 3 months: for the compressor using air-cooled cooling, the condensing fan should be regularly overhauled and the condenser should be decontaminated and dusted to ensure its good ventilation and heat exchange performance; For the compressor to use water-cooled cooling, in addition to ensuring its inlet pressure and inlet temperature, the corresponding flow
must also be guaranteed.
4.
The water path of the constant temperature and humidity test chamber is not smooth, which is easy to lead to water blockage
.
5.
If the equipment needs to be relocated, it should be carried out under the guidance of technical personnel to avoid unnecessary damage or damage to the equipment
.
6.
Adhere to the professional management of special personnel, and send special personnel to the supplier factory for training and learning
from time to time if conditions permit.
To obtain more professional maintenance and repair experience and ability
.
7.
Constant temperature and humidity test chamber circulating fan and condenser fan cleaning and balance: Similar to cleaning evaporators, due to the different working environments of the test chamber, a lot of dust and other small particles will condense on the circulating fan blades and condenser fans, which should be cleaned
regularly.
8.
When the constant temperature and humidity test chamber is not used for a long time, the product should be powered on regularly every half month, and the power-on time is not less than 1 hour
.
9.
The constant temperature and humidity test chamber cannot be continuously turned on and off within 1 hour, which can easily lead to the service life
of the constant temperature and humidity test chamber.