    The double glass reactor is designed as double glass, the inner layer can be put into reaction medium for stirring reaction, and the interlayer can be connected with different cold and heat sources (freezing liquid, hot water or hot oil) for circulating heating or cooling reaction Under the condition of constant temperature and closed glass reactor, stirring reaction can be carried out under normal pressure or negative pressure according to the use requirements, and reflux and distillation of reaction solution can be done It is an ideal pilot plant and production equipment for modern fine chemical plants, biopharmaceuticals and new material synthesis In daily use, the maintenance of double glass reaction kettle is very important Today's editor will introduce the maintenance methods for you: 1 Carefully check the instrument before use, whether the glass bottle is damaged, whether the interfaces are consistent, and pay attention to handle with care 2 Wipe each interface with soft cloth (instead of napkin), and then apply a little vacuum grease (the vacuum grease must be covered after use to prevent the lime sand from entering.) 3 Each interface shall not be tightened too tightly It is necessary to loosen and activate regularly to avoid long-term locking leading to connector seizure 4 Turn on the power switch first, and then let the machine run from slow to fast When the machine is stopped, turn off the switch 5 The polytetrafluoroethylene switches at all places shall not be over tightened, which is easy to damage the glass 6 After each use, all kinds of oil stains, stains and solvent remaining on the surface of the machine must be wiped with a soft cloth to keep it clean 7 After the machine is stopped, loosen the polytetrafluoroethylene switches, which will deform the polytetrafluoroethylene piston if it is still in the working state for a long time 8 Clean the sealing ring regularly by taking off the sealing ring, checking whether there is dirt on the shaft, wiping it with a soft cloth, then applying a little vacuum grease and refitting it to keep the shaft and the sealing ring smooth 9 The electrical part shall not be allowed to enter into water, and shall not be damped 10 The original accessories must be purchased Using other accessories at will will will cause fatal damage to the machine 11 When making any repair or inspection to the machine, it is necessary to cut off the power supply and water source first Note: This equipment belongs to fragile products Please handle it with care when using The damage of fragile products is not covered by our warranty If the customer needs, we need to charge the corresponding cost.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Related Articles

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.