    The service life of double glass reaction kettle is closely related to the daily maintenance besides the frequency converter, glass and motor In order to prolong the service life of double glass reactor and protect your interests, please read this section carefully The interlayer of double glass reaction kettle can provide high temperature reaction (high temperature can reach 300 ℃) or low temperature reaction (low temperature can reach - 80 ℃); however, these daily works are very harmful to double glass reaction kettle, so daily maintenance is very important The following are the daily maintenance methods of the double glass reaction kettle: 1 Check whether the interfaces of the instrument are consistent, and handle with care 2 Each interface shall not be tightened too tightly It is necessary to loosen and activate regularly to avoid long-term locking leading to connector seizure 3 Wipe each interface with soft cloth (instead of napkin), and then apply a little vacuum grease (the vacuum grease must be covered after use to prevent the lime sand from entering )4 Clean the sealing ring regularly by taking off the sealing ring, checking whether there is dirt on the shaft, wiping it with a soft cloth, then applying a little vacuum grease and refitting it to keep the shaft and the sealing ring smooth 5 The polytetrafluoroethylene switches at all places shall not be over tightened, which is easy to damage the glass 6 After the machine is stopped, loosen the polytetrafluoroethylene switches, which will deform the polytetrafluoroethylene piston if it is still in the working state for a long time 7 Turn on the power switch first, and then let the machine run from slow to fast When the machine is stopped, turn off the switch 8 After each use, all kinds of oil stains, stains and solvent remaining on the machine surface must be wiped with a soft cloth to keep it clean 9 The electrical part shall not be allowed to enter into water, and shall not be damped 10 The original accessories must be purchased Using other accessories at will will will cause fatal damage to the machine.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.