Constant temperature and humidity test chamber environmental test chamber due to long-term application, some of the cat plague dust stored in the gas will enter the cabinet, with the time of lifting dust will be deposited larger, so that the environmental test chamber in the whole process of application will appear many problems
.
Therefore, in life, it is also necessary to pay attention to the maintenance of machinery and equipment on time, which can improve the service life
of the environmental test chamber.
Liuqin Technology as an expert in environmental testing equipment, and show a series of environmental test equipment pre-sales service, sale, after-sales maintenance services, the following for everyone to introduce in detail the constant temperature and humidity test box environmental test box maintenance is a very critical level - constant temperature and humidity test box environmental test box ash removal method
。 The key points of the ash removal method of the environmental test chamber of the constant temperature and humidity test chamber are as follows: First, the internal residue of the environmental test chamber should be eliminated before the operation process; The high and low voltage distribution room is cleaned about once a year, and the dust in the room can be sucked out by the vacuum cleaner when cleaning; The outside of the shell must be cleaned about once a year, and scrubbed with soap solution when cleaning
.
Second, the water storage tank in the air humidifier should be dismantled and replaced once a month to ensure the cleaning of the water body, and the humidifier water tray should be cleaned once a month to ensure smooth flow
.
Third, check the operation of the overheating protection device, the high value of the overheating maintenance setting is increased by 20 °C ~ 30 °C
.
When the temperature in the experimental cabinet rises to the setting point of overheating maintenance, the power supply system of the electric heater is terminated, the "OVERHEAT" overheat alarm light is on but the fan is still running, if it is operated for a long time and no one is guarded, please try to check the overheating protection device before running, whether it is set up properly (the setting of the dry bulb temperature overheating protection device is 120 ° C).
Fourth, the use of wireless vacuum cleaner to cool the heat pipe heat dissipation wire mesh adhesion dust suction or the use of pressure gas spray dust
.