echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Active Ingredient News > Drugs Articles > How to use toxic gas detector

    How to use toxic gas detector

    • Last Update: 2019-11-29
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    1 The detector shall be calibrated and tested in time No matter what the instrument is, it shall be checked and calibrated carefully before use, especially for toxic gas detector If the instrument is not calibrated and tested in time before use, the accuracy of the instrument itself may deviate In this case, if the firefighters enter the site of toxic gas leakage, it may cause serious casualties, with unimaginable consequences Therefore, it is necessary to calibrate and test the gas detector in time before using it 2 Pay attention to the concentration measurement range of the detection instrument The toxic gas detector has its fixed detection range Only when the measurement is completed within the measurement range, can the instrument measure accurately If the sensor is out of the measurement range for a long time, it may cause damage to the sensor For example, the toxic gas detector, working in a high concentration of toxic gas environment for a long time, may cause sensor damage Therefore, if the fixed instrument sends out out out out of limit signal, the measuring circuit should be closed immediately to ensure the safety of the sensor 3 Pay attention to the use environment of the detection instrument During the use of the toxic gas detector, pay attention to the prevention of electromagnetic interference If there is electromagnetic interference in the use process, there will also be errors In addition, the temperature, humidity, pressure, wind speed, wind direction, whether there is dust, whether there is corrosiveness, whether there is other gas interference and so on will also affect the detection effect of toxic gas monitor 4 Pay attention to the maintenance of toxic gas detector Don't place or hang articles on the detector The installed gas detector can't move the position of the device at will When purchasing, try to choose the product that can be replaced by the sensor probe, so as to facilitate the later use In the process of using toxic gas detector, we must strictly follow the above points to ensure the safe and reliable operation of the instrument  
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.