    Isolation point air disinfection device

    • Last Update: 2022-01-22
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com

    4.


    In order to implement the requirements for normalized prevention and control of the new crown pneumonia epidemic, guide all localities to do a good job in the construction of large-scale centralized isolation points, "combined peace and war" isolation places and other comprehensive centralized isolation places and the renovation of scattered isolation hotels


    Setting standards for centralized isolation of medical observation points


    Sterilization and disinfection device for exhaust port

    1.


    Products use a special high-energy ultraviolet light UV irradiation high ozone gas under irradiation of high-energy ultraviolet light, degrade into low molecular weight compounds, such as CO2, H2O and the like


    High-energy UV beam is used to crack the molecular bonds of bacteria in the gas, destroy the nucleic acid (DNA) of bacteria, and then conduct oxidation reaction through ozone to achieve the purpose of purifying and killing bacteria.


    1.


    Due to the existence of unbalanced and unsaturated molecular attraction or chemical bond force on the surface of activated carbon, when the surface of activated carbon is in contact with gas, it can attract gas molecules to concentrate and keep them on the surface of activated carbon.


    Photo-oxygen activated carbon combines photolysis oxidation technology and activated carbon adsorption technology to perform synergistic purification treatment from gasification to gasification.


    2.


    The large-area PTFE sterilizing filter element is adopted, and the quick-loading structure has a filtration accuracy of 0.


    2.


    1.


    2.


    O2+e(3.


    H2O+e(5.


    The research shows that the oxidation potential (2.
    8eV) of active radical·OH is 35% higher than the oxidation potential (2.
    07eV) of ozone which is very oxidizing
    .
    · The reaction rate of OH radicals with organics is several orders of magnitude higher
    .
    Moreover, the reaction of OH radicals to oxidized pollutants is non-selective, and can trigger a chain reaction to directly oxidize most of the harmful substances in the polluted air into carbon dioxide and water or minerals
    .
    Its mechanism of action is as follows:

    H2S+ OH→HS+H2O

    HS+O2+O2++O2-→SO3+H2O

    NH3·OH→NH2+H2O

    NH2+O2+O2++O2→→NOX+H2O

    CH2O+ O2++O2→+·OH→H·COOH+H2O

    3.
    Installation precautions

    The temperature of the gas is controlled below 80°C
    .
    Because the temperature is too high will affect the effect and equipment life
    .
    If the sterilization and disinfection box is installed on the bracket, it should be tightly connected with the bracket; the connection between the box body and the exhaust duct must be sealed; the box body can be installed indoors or outdoors, but there should be enough The space is used for maintenance and repair ; the equipment is regularly maintained and cleaned according to the usage
    .
    The box body should be grounded reliably; during installation, it is not allowed to bump the UV tube, and foreign objects are strictly prohibited from falling into the purifier; the box body and the electrical connections in the electric control box should be reliable and correct
    .
    The external power supply of the equipment is 220V/380V.
    Due to the strong ultraviolet rays in the equipment, dark sunglasses should be worn during maintenance to avoid eye damage
    .
    The air outlet of the equipment must be open to the outside, and there should be space around the equipment and external ventilation, so that the generated ozone can be dissipated to the outside
    .
    Otherwise, it will cause ozone enrichment, which will cause harm to personnel and safety hazards such as fire
    .
    It is strictly forbidden to use the device in a closed space
    .

    Four.
    Safety Precautions (Warning)

    1.
    This equipment is live, and non-professionals are prohibited from operating it
    .

    2.
    If there is a fan when starting up, turn on the fan first and then turn on the device.
    When stopping, turn off the device first and then turn off the fan
    .

    3.
    The ultraviolet light wave should avoid direct exposure to the human body, and it is strictly forbidden to look directly at the lamp tube with the naked eye
    .

    4.
    The equipment should be protected from water, dust and oil, especially that high temperature and sparks can easily cause damage to the built-in lamp ballast (plasma electric field, power supply), so as to avoid short-circuiting the equipment and causing fire
    .

    5.
    Timely and regularly replace filter cotton, activated carbon, etc.
    , and promptly clean the inside of the box and the lamp tube (plasma electric field) to keep it clean
    .
    Regularly check the lamp ballast and wiring, and replace it in time if it is damaged
    .

    6.
    The equipment should be placed in an open space, and it is strictly forbidden to stack flammable and explosive materials near the equipment
    .

    7.
    It is forbidden to use this equipment for flammable and explosive gases and gases that cannot be treated by oxidation
    .

    five.
    Instructions for use and maintenance

    1.
    This equipment is installed horizontally, and the shell of the UV sterilizer shall not be subjected to external pressure
    .

    2.
    Select the installation location reasonably, and pay attention to the waterproof and moisture-proof of the electric control part
    .

    3.
    Quartz glass sleeves and UV lamps are precious and fragile crystals, and bumps should be avoided during transportation, installation and use
    .

    4.
    Keep clean and dust-free gas entering the equipment
    .

    5.
    The equipment cannot be opened at will, and the power must be turned off before repairing and overhauling the equipment
    .

    6.
    Regular inspection: to ensure the normal operation of the germicidal lamp, repeated switching will seriously affect the service life of the lamp
    .
    A UV germicidal lamp has a lifespan of up to 12,000 hours
    .

    7.
    Regular cleaning: According to the usage, the ultraviolet quartz lamp tube and quartz glass sleeve need to be cleaned regularly, wipe the lamp tube with alcohol cotton ball or gauze, remove the dirt on the quartz glass sleeve and wipe it, so as not to affect the transmission of ultraviolet rays rate, which affects the processing effect
    .

    8.
    Activated carbon should pay attention to moisture-proof and fire-proof, so as not to affect the treatment effect and cause fire hazards
    .

    9.
    Activated carbon is easy to be saturated, and the owner regularly replaces the activated carbon according to the actual use
    .

    6.
    Filling method of activated carbon

    1.
    Drawer-type activated carbon adsorption device: open the drawer, and the honeycomb activated carbon bricks are arranged with uniform pores facing upwards
    .
    If the activated carbon particles are filled, the activated carbon particles can be evenly distributed in the drawer
    .

    2.
    Vertically installed plate activated carbon adsorption device: open the external bolts, pull out the activated carbon plate, place the pores of the honeycomb activated carbon brick in the same direction, and keep the vertical installation left and right ventilation
    .

    3.
    After the activated carbon is replaced, the drawer and cover are restored and fixed with bolts
    .

    Product introduction

    Medical vacuum systems are widely used in medical and surgical operations to provide timely and reliable suction power
    .
    In the environment, increasing sensitivity to contamination and protection against infection make filtration a necessity for these systems
    .
    The necessity of vacuum system filtration has become widespread
    .
    Insufficient inlet filtration can damage the vacuum pump, destroy the vacuum, cause contamination and equipment to stop working
    .
    Inlet line contaminants include particles, dust, moisture and other gases
    .
    Outlet emissions can also include particulates, oil and noxious gases
    .
    Professional inlet and exhaust filters can effectively deal with these pollutants
    .

    Professional sterilization filtration has the danger of carrying a large number of germs in the pipeline and outlet of any vacuum system.
    In order to protect the health of patients, medical staff, other service personnel and the general public, countries have proposed to install and maintain bacterial filtration many years ago.
    device
    .
    Not installing or maintaining a sterilizing filter in front of the vacuum pump will not only damage the vacuum pump, but also make the vacuum pump a source of bacterial contamination
    .
    The right temperature and humidity for a vacuum pump is an ideal breeding ground for bacterial growth, which technically puts the vacuum pump itself at risk, leading to vacuum pump replacement
    .
    Vacuum sterilization filter performance requirements

    According to the BS3928:1969 test method, the filtration efficiency exceeds 99.
    995% and the pressure difference does not exceed 30mbar at a vacuum of 630mbar.
    Instructions for filter replacement and disposal are required.
    AS2896 medical gas systems states inlet filters as follows: Medical inlet filters should be Bacterial filter, select the appropriate size so that the pressure difference does not exceed 3.
    5KPa, the filter element should meet the filtration efficiency of 0.
    01μm required by ISO8573.
    1
    .
    China GB50751-2012 Technical Specifications for Medical Gas Engineering on sterilizing filters: 5.
    2.
    16 Filtration precision 0.
    01-0.
    2μm, filtration efficiency 99.
    995%
    .
    The sterilizing filter should be maintained and replaced in time to avoid excessive pressure difference affecting the system flow
    .

    The negative pressure sterilization filter mainly adopts a large-area sterilization filter element, a quick-loading structure, and a filtration accuracy of 0.
    22μ0.
    01μ.
    It is regularly sterilized by clean steam at 121°C, and can remove 99.
    995% of bacteria and various bacteriophages
    .
    It is a necessary link in the medical center suction system industry, and the sterilizing filter is the choice for negative pressure air sterilization
    .
    The sterilizing filter is made of 304 or 316L stainless steel shell, and is mirror polished to achieve no dead corners of parasitic bacteria
    .
    The filter element of the sterilizing filter adopts a steam sterilized PTFE pleated filter element
    .
    The filter element has the characteristics of high pressure resistance, high temperature, hydrophobicity and high density
    .


    Hangzhou Jiajie Electromechanical Equipment Co.
    , Ltd.

    HANGZHOU JIAJIE MECHATRonICS DEVICE CO.
    , LTD

    Address: No.
    1191, Linding Road, Jianggan District, Hangzhou (Building B, Jiadewei Industrial Park) Postal Code: 310021

    Person in charge: Zhu Xiaoping Tel: 0571-28811100

    Fax: 0571-85142370 Phone: 13588388654

    Website: http:// class="MsoNormal" > Email: jjzxp0707@163.
    com


    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.