    Maintenance of automatic hard capsule filling machine

    • Last Update: 2014-08-18
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    (1) when the machine works for a long time, the parts and components that are in direct contact with the drugs shall be cleaned regularly When the batch of drugs is replaced or the downtime is long, the parts and components shall also be cleaned (2) the transmission mechanism under the working table of the machine shall be regularly and appropriately added with lubricating oil (grease) to reduce the wear of moving parts (3) the oil quantity of the main drive reducer shall be checked once a month If it is insufficient, oil shall be added in time, and the lubricating oil shall be changed once every half a year The lubricating oil shall be changed once every 3000h of operation of the indexing box at the rotary table station, generally 90 × oil shall be used (4) the safety clutch plays a protective role when the machine is overloaded The clutch should not slip when the load is normal, but it may also slip when it is used for a long time When it slips when it is used normally, the round nut of the clutch can be tightened to ensure the normal operation of the machine and play a protective role (5) the vacuum separator of the vacuum system mainly plays the role of sucking the capsule into the upper and lower modules and separating the cap and the body during the filling of the hard capsule If the cap and the body cannot be separated, the subsequent filling will not be carried out Every time the rotary table of the machine runs 1 station, the main shaft of the machine rotates 1 cycle, and the vacuum separator moves up and down once under the action of the cam If the separation of capsule cap and body is not smooth, check the gap between the upper plane of vacuum separator and the lower plane of the lower module If the gap is too large, the vacuum degree of vacuum system will not reach the vacuum degree required by the separation of cap and body (about 0.05Mpa) If the gap is too small, it is easy to produce head impact and deform the lower module When the position of the vacuum separator needs to be adjusted, use the handle to turn the main motor shaft to make the vacuum separator rise to the Zui high position, loosen the lock nuts (one is left-hand nut and one is right-hand nut) at both ends of the adjusting rod under the machine table, then rotate the adjusting rod to adjust the height of the vacuum separator, then lock the nuts, and use the handle to turn the main motor shaft for test until it is appropriate The vacuum degree shall be read out on the vacuum gauge on the operation panel of the machine When the vacuum is too high, the vacuum degree regulating valve can be opened properly When the vacuum is too low, the vacuum degree regulating valve can be closed or closed The filter of the vacuum system shall be opened regularly to remove the blocked dirt, so as to ensure that the vacuum system has enough vacuum (6) the transmission chain shall be inspected once a week and added with proper amount of grease It is necessary to tighten it again When the chain is too loose and needs to be tightened again, the tensioning wheel shall be moved for adjustment, but the chain shall not be opened or taken off from the sprocket, so as to avoid disturbing the movement sequence of the whole mechanism and preventing the mechanism movement interference
    (7) the machine has 5 transmission cams, 5 cams are installed on the main shaft of the machine, which are respectively * cams for capsule distribution in station 2 *, cams for separating capsule cap and body by using vacuum separator in station 2; cams for removing unopened capsules in station 6; cams for locking filled capsules in station 8; cams for project 9 The cam used to push the finished product out.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.