1 Place the instrument on the platform or workbench in the dry indoor place, and keep it in the horizontal state Install the socket and leakage protection switch in the power line, and install the grounding wire 2 Put the items to be cultivated into the box, close the door, turn on the power, turn on the power switch, the indicator light is on, indicating normal operation, and the instrument shows the temperature of the workshop 3 The knob switch of the control instrument is adjusted to the required temperature, and heating starts in the working room The green light on the control instrument indicates power on and heating up, the red light indicates power off and heat preservation, and the alternating change of the red and green lights indicates entering the constant temperature state About 30 minutes after entering the constant temperature state, the set temperature is basically the same as the actual temperature 4 If the setting temperature needs to be changed, the knob can be adjusted at any time After the operation, turn off the power switch II Maintenance 1 The instrument shall be placed in a room with good ventilation conditions, and the indoor relative humidity shall not be greater than 85% Inflammable and corrosive articles shall not be placed around it 2 The instrument is not equipped with anti explosion device, and inflammable and explosive materials cannot be placed in the working room 3 The inside and outside of the box shall be kept clean If it is not used for a long time, the dust cover shall be covered and placed in a dry room 4 In the process of use, the air hole shall be properly opened to release the humid gas If the temperature changes abnormally, shut down the machine in time for slag detection 5 Cut off the power supply when placing articles to ensure the operation safety 6 It is forbidden to place the articles on the cover plate of furnace wire to avoid burning or damaging the equipment Shangyu Star Instrument Equipment Co., Ltd is located in Daoxu Town, Shangyu District, Shaoxing City, Zhejiang Province It is an enterprise integrating production, product development, processing and trade The company's main products: drying box series, incubator series, laboratory muffle furnace series, distiller series, as well as clean workbench, air shower room, ventilation cabinet, biosafety cabinet and other complete sets of purification equipment The company has a strong technical research and development team, a strong after-sales service system, is the leading manufacturer of complete set of laboratory equipment in China, welcome customers to buy