echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Biochemistry News > Microbiology News > Phage outbreak and response measures

    Phage outbreak and response measures

    • Last Update: 2021-01-23
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com

    what we're doing is E. coli's
    genetic
    engineering bacteria. Some time ago even three batches were infected with
    phage
    , one batch a day, we do is 60T fermentation tank.
    of phage outbreaks:
    1, PH has been rising, will be relatively high (we normally 7.00, rebound to 7.8).
    2 and DO will soon pick up, rising to more than 130%.
    3, the fermentation liquid thinned, the OD value quickly decreased.
    4, the mirror can not see any bacteria.
    5, the outbreak time is earlier than once, are pre-fermentation.
    phage outbreak is very fast, then 30 minutes or so, when we just moved the fermentation cycle is so fermentation cycle 3 to 5h, too terrible;
    outbreak after the whole plant bleaching powder spraying, new Jieer spraying, formaldehyde fumigation, for several days in a row every day to do hygiene;
    personal views:
    phage outbreak cause analysis
    1, when the workshop replaced with a new leader, did not pay attention to environmental health;
    2, when the workshop also carried out transformation, health is only slightly done, for 4 months in a row;
    3, workshop transformation, disinfection of the whole gas, some small exhaust are discharged in the workshop, but also directly discharged into space, resulting in the entire workshop humidity is
    relatively large
    , laboratory personnel are not trained in place, sampling directly discharged, without going through the waste tank directly discharged into the sampling tank;
    6, the duty room staff also did not have training in place, for the treatment of foam sometimes leads to escape fluid,
    7, just started infecting phages, did not attract enough attention, did not take appropriate measures;
    people think that the prevention of phages is the first important health environment, as well as workshop personnel management, in strict accordance with
    GMP
    implementation. I hope we can all discuss the treatment of phages.
    measures to be taken after the phage outbreak:
    discontinuation, cleaning and disinfection of the room with sodium hypochloride, high temperature sterilization of all appliances or soaking with sodium hypochloride.
    : effective chlorine concentration of 2500 ppm, greater than 30min;
    shaker
    fumigated with formaldehyde plus potassium permanganate, and then treated with ultraviolet radiation for half an hour;
    If the concentration of phages in the air is also high, it can be fumigated with formaldehyde, 3g/m2, or with ultraviolet radiation, but be careful, as both methods can cause corrosion to the instrument. Water should also be treated with sodium hypochlorate. Air phage detection: double-layer flat, the lower layer is the production of bacteria or sensitive bacteria
    culture
    -base, the upper layer is nutritious broth soft
    agar
    , double-layer agar plate open cover put 30min, 30 degrees culture overnight. See if there are phage spots.
    't work, we'll have to stop production. Or change to
    strain of
    , because phages have very good specificity. And the most fundamental is to develop laboratory safety norms, to eliminate the spread of live bacteria.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.