    Problems in operation of biochemical incubator

    • Last Update: 2014-05-20
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    Biochemical incubator has a strict and complex process in the production process, so in daily use, we should learn how to care for it carefully Some things in the operation of biochemical incubator are taboo, and improper operation methods are resolutely not operated The following small braids take you to understand the problems to be paid attention to in operation 1 The biochemical incubator shall be installed in the place with small change of temperature and humidity as far as possible, and the three pin plug and socket shall be properly grounded 2 Before the start-up of biochemical incubator, it is necessary to be fully familiar with and understand the instructions of various supporting instruments and meters, and master the correct use methods 3 It is strictly prohibited to contain volatile chemical solvents Explosives and combustible gases are placed in boxes Flammable sprays should not be used near incubators, so as to avoid sparking of electric sparks 4 Check the air circuit frequently for air leakage 5 Biochemical incubator has power-off protection function, so the compressor should be started again for about one and a half minutes after shutdown, so as to better protect the compressor 6 The distance between the condenser and the wall of the biochemical incubator shall be greater than 100 mm, the side of the incubator shall have a gap of 50 mm, and the top of the incubator shall have a space of at least 300 mm to ensure good heat dissipation 7 When carrying, repairing and maintaining the biochemical incubator, collision and shaking vibration shall be avoided, and the Zui inclination shall be less than 45 degrees 8 Turn off the main power supply and the power switch at the back of the equipment when it is out of use for a long time ? at the same time, when the biochemical incubator is working, frequent opening of the door shall be avoided to keep the temperature stable and prevent dust and dirt from entering the working room 9 The inside and outside of the box shall be kept clean every day and cleaned after each use If you don't use it for a long time, wipe the inner tank of the box wall and the surface of the equipment frequently to keep it clean and increase the transparency of the glass Do not wipe the outer surface with acid, alkali or other corrosive solution 10 Turn off the power switch after the cultivation If you do not take out the test sample immediately, do not open the door.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.